Product Overview
ATEX Thermostats | Zone 1 & Zone 2 (IIA, IIB, IIC) & Zone 21 & Zone 22 (IIIA, IIIB, IIIC)
Inline Encapsulated Thermostats
EXHEAT FXT-M inline encapsulated thermostats have been established as temperature control solution where space is at a premium with the capability of changing small and medium sized heaters to be able to retain a pre-determined ambient temperature for heating and air warming of Zone 1 & Zone 2 (Flammable Gas) and Zone 21 & Zone 22 (Dust) explosive atmospheres according to ATEX Directive.
The FXT-M is composed of a unique electronic potting compound, stainless steel shroud and polyolefin sheath. Robust and lightweight in design a main benefit of the thermostat is it requires minimal maintenance.
Similar to the FXT-DR and FXT-DI thermostats the FXT-M can be linked with the FX hazardous area compact enclosure heaters designed specifically for frost protection, anti-condensation and temperature control – operating in ambient temperatures up to +80°C.
Alternatively, when supplied with up to 10m of cable, the FXT-M can be installed to control any electrical item inside a cabinet or enclosure.
Features of EXHEAT FXT-M Inline Encapsulated Thermostats
- Protection Method: Encapsulated thermostats
- Voltage: 110 to 277VAC
- Ambient Temperature: -50°C to +80°C
- Temperature Class: T5 (T100°C) to T6 (T85°C). T5 and T6 thermostats are suitable for use in T1 to T4 (T450°C to T135°C) hazardous environments. Ensure ambient temperature limits are adhered to
- Cable: 3M standard (up to 10M available on request)
- Ingress Protection: Inline encapsulated thermostats with IP66
ATEX Certification & Installation
Certification: ATEX/IECEx II 2 G D
Ex mb IIC T6 to T5 Gb
Ex mb IIIC T85°C to T100°C Db
CU TR (EAC)
CU-TR.012/2011 CERTIFIED 1 Ex db IIC T6…T3 Gb X
Ex tb IIIC T85°C…T200°C Db X
CSA
Class I Div 2, Groups A, B C and D T6…T5
Class III, Div 2: Class II Div 2, Groups E, F & G.
Class I, Zone 1, AEx db IIC T6…T4 Class III, Zone 21:
Type 4 Ex mb IIC T6…T4 Gb Ex mb IIIC T85°C..T135°C Db IP66
Please download EXHEAT FXT-M hazardous area thermostats O&M manual for full details on installation and maintenance procedures – this includes wiring diagrams, earth connection and pre installation inspection and checks.
Applications
- Acoustic enclosures
- Condensation prevention
- Control/monitoring panels
- Control valve housings
- Fire hose cabinets
- Frost protection
- Generators
- Instrumentation cabinets
- Manifolds
- Motor enclosures/cabinets
- Valve blocks
Specification
Since 1985 as Leaders in ATEX Innovation we can facilitate succession planning for the replacement of obsolete, non-conformant and legacy equipment – we are the provider of innovative solutions to ensure ATEX and IECEx Compliance for Electrical, HVAC & Process Instrumentation systems in the explosive atmosphere industries.