Katronic KATflow 230 Ultrasonic Clamp-On Flowmeter (Portable)

Non-Hazardous & Hazardous Area Flowmeters

CategoryProcess Instrumentation
  • Quoted to your quantity
  • Documentation on request
  • International delivery

Product Overview

Non-Hazardous & Hazardous Area Flowmeters

Ultrasonic Flow Meters

Katronic’s KATflow 230 is a portable flowmeter which utilises ultrasonic technology to measure the flow rate of liquids within pipes without entering the pipe. The KATflow 230 is an advanced specification portable flowmeter capable of two measurement channels so that either two pipes can be monitored simultaneously or it can used to improve accuracy in non-ideal conditions.

KATflow 230 flowmeters are suitable for pipe diameters ranging from 10mm up to 6,500mm and have a robust IP65 aluminium enclosure and has a selectable three-line LCD display and full keypad.

Stainless steel sensors, cables and connectors are supplied as standard for temperature ranges from -30ºC to +250ºC and a large data logger and software are also supplied for sampling and data transfer.

Katronic KATflow 230 Ultrasonic Clamp-On Flowmeter (Portable) – Features

  • Pipe diameter range 10mm to 6,500mm
  • Temperature range for sensors – -30ºC to +250ºC (-22ºF to +482ºF)
  • Robust IP65 aluminium enclosure
  • Selectable three-line LCD display and full keypad
  • Battery life up to 24 hours with easily replaceable battery cartridge
  • Measurement of two flows simultaneously
  • Dual flow monitoring with sum, average, difference and maximum calculations
  • PT100 inputs for heat quantity (thermal energy) measurement
  • Process output options including current, open-collector, relay
  • Large data logger and software for sampling and data transfer
  • Stainless steel sensors, cable and connectors as standard
  • Optional – Pipe wall thickness gauge
  • Optional – Crush-proof IP67 transport case or lightweight soft case
  • Optional – Special waterproof solution available for harsh environmental conditions
  • Optional – KATdata+ software for data evaluation
  • Optional – Expansion box for additional input or output configuration and special solutions

The KATflow 230 is an ideal flowmeter solution for applications including heating, ventilation and air conditioned (HVAC) measurements, large pipe measurement with two sensor pairs in ‘X’ configuration, temporary replacement of conventional in-line flowmeters, building surveys on large facilities, efficiency monitoring of heat exchangers and more.

Katronic KATflow 230 Ultrasonic Clamp-On Flowmeter (Portable) – Technical Specification

Visit Katronic KATflow 170 for hazardous area flowmeters with ATEX Certification for metering the flow in Zone 1 and Zone 2 explosive atmospheres.

Technical Specifications

CategoryProcess Instrumentation
Flowmeter Performance
Flowmeter Measuring PrincipleUltrasonic transit time difference
Flow Velocity Range0.01 to 25m/s
Resolution0.25mm/s
Repeatability0.15% of measured value, ±0.015m/s
AccuracyVolume Flow: ±1 to 3% of measured value depending on application ±0.5% of measured value with process calibration Flow Velocity (Mean): ±0.5% of measured value
Turn Down Ratio1/100 (Equivalent to 0.25 to 25m/s)
Measurement Rate100 Hz (Standard)
Response Time1s
Damping of Display Value0 to 99s (Selectable by user)
Gaseous and Solid Content of Liquid Media<10% of volume
General
Enclosure TypePortable
Degree of ProtectionIP65 according to EN 60529
Operating Temperature-10 to +60ºC (+14 to +140ºF)
Housing MaterialExtruded aluminium, Al MG Si 0.5, lids die-cast zinc alloy GD-Zn AL 4 CU 1
Measurement Channels1 or 2
Calculation FunctionsAverage, difference, sum, maximum (dual-channel use only)
Power SupplyInternal rechargeable batteries: 8 x NiMH AA 2850 mAh Power adapter: 100 to 240V AC input, 9V DC output External battery pack: 12V 105Ah, 25kg (optional)
Operating TimeUp to 24 hour with fully charged internal batteries
DisplayLCD graphic display, 128 x 64 dots, backlit
Dimensions266mm (H) x 168mm (W) x 37mm (D)
WeightApprox 2kg
Power Consumption<5W
Operating LanguagesEnglish, French, German, Dutch, Spanish, Italian, Russian, Czech, Turkish, Romanian (Others on request)
Communication
TypeRS 232, USB cable (optional)
Transmitted DataMeasured and totalised value, parameter set and configuration, logged data
Internal Data Logger
Storage CapacityApprox 30,000 measurements (each comprising up to 10 selectable measurement units), logger size 5MB Approx 1000,000 measurements (each comprising up to 10 selectable measurement units), logger size 16MB
Logged DataAll measured and totalised values, parameter sets
KATdata+ Software
FunctionalityDownload of measured values/parameter sets, graphical presentation, list format, export to third party software, online transfer of measured data
Operating SystemsWindows 8, 7, Vista, XP, NT, 2000 Linux
Quantity and Units of Measurement
Volumetric Flow Ratem³/h, m³/min, m³/s, l/h, l/min, l/s USgal/h (US gallons per hour), USgal/min, USgal/s bbl/d (Barrels per day), bbl/h, bbl/min
Flow Velocitym/s, ft/s, inch/s
Mass Flow Rateg/s, t/h, kg/h, kg/min
Volumem³, l, gal (US gallons), bbl
Massg, kg, t
Heat FlowW, kW, MW (with heat quantity measurement option)
Heat QuantityJ, kJ, kW/h (with heat quantity measurement option)
TemperatureºC (with heat quantity measurement option)
Process Inputs (Galvanically Isolated)
Current0/4 to 20mA active (R load < 500Ω), 16 bit resolution, U = 30V, accuracy: 0.1%
Digital Open-CollectorValue: 0.01 to 1000/unit, width: 1 to 990ms, U = 24V, l max = 4mA
Digital RelayForm A SPST (NO), U = 48V, l max = 250mA
Building ServicesSingle or dual-channel heat quantity measurement Efficiency monitoring of heat exchangers Pump testing and inspection
Water and WastewaterDrinking water and effluent measurements Dual-channel measurements on large pipes for increased accuracy Screened sludge monitoring
Manufacturing and ProcessMeasurement of hydraulic oil Fuel consumption measurements Measurement of paint flows
Power GenerationMeasurement of cooling circuits Verification of main water inlets CHP monitoring (Combined Heat and Power)
Marine and ShipbuildingHeavy fuel oil measurements Balancing of hot water systems Monitoring of sea water inlets
General IndustryCIP system testing In-line flowmeter performance verification Temporary replacement of conventional in-line flowmeters

Request Information About This Product

Tell us your quantity and requirements — we reply within one business day.

Have a product requirement?

Share your specifications and quantities. Our team will review your request and come back with sourcing options and a quotation.