ATEX Plugs, Sockets & ConnectorsMarechal 2514015 | Female Socket-Outlet
Product Code: 2514015

Product Range: Marechal SPeX (Single Pole) ATEX Plugs & Sockets
Product Range: Marechal SPeX (Single Pole) ATEX Plugs & Sockets
REQUEST A QUOTE
+44 (0)191 410 4292
Marechal SPeX plugs and sockets are compact, watertight hazardous area connectors with current ratings up to 680A, 1000V AC / 1500V DC and ATEX certification for Zone 1 & Zone 2 (and Zone 21 & 22 for dust). SPeX connectors are automatically IP65/IP66 when connected and include a reliable mechanical and electrical interlocking system. SPeX belongs to the Marechal Plugs, Sockets & Connectors range, designed for safe and reliable power connections in demanding industrial environments.
SEE TECHNICAL SPECIFICATIONS
GO TO DOWNLOADS
Product Overview
Technical Specifications
ATEX Classification
Key Benefits
Install & Operation
Downloads
The Marechal SPeX is part of the Marechal Hazardous Area Plug range, designed for demanding environments where robust, watertight connections and controlled operation are required. SPeX is ATEX certified for Zone 1 & Zone 2 and supports high current single pole power distribution up to 680A (depending on category and cable).
SPeX connectors are automatically IP65/IP66 when connected, with a reliable interlocking system that supports safe procedures for connection and disconnection. Selection should be based on ambient temperature, cable cross section and the required ATEX temperature class.
Contact our trusted experts – confirm the correct SPeX selection for your project (supply type AC/DC, current, cable size and ambient temperature range).
UK & export projects supported with fast worldwide delivery.
Contact Our Experts
For correct selection, base current rating on the ATEX classification table (ambient temperature and cable cross section).
Share your cable cross section and ambient temperature range and we’ll confirm the correct SPeX configuration and ATEX classification for your project.
✔ Current ratings up to 680A (dependent on category and cable)
✔ High voltage capability: 1000V AC / 1500V DC
✔ ATEX certified for Zone 1 & 2 (Gas) and Zone 21 & 22 (Dust)
✔ Automatically IP65/IP66 when connected
✔ Robust construction with IK08 shock resistance
✔ Mechanical keying (5) + visual identification to support correct matching
✔ Pre-wired pilot circuit 6A / 250V to support interlocking
✔ Designed to support strict connection/disconnection procedures in hazardous areas
Key safety notes: Electrical interlocking with a contactor is compulsory. The pilot circuit supply must be protected against transient over-voltages of 4kV using an appropriate isolating device.
View assembly, wiring & operation guidance
Assembly: Insert cable through the cable gland and handle or through the inclined sleeve.
Wiring of the pilot wires: Use flexible conductors 0.5–1.0mm². Connect to microswitch wires using the insulated crimp lugs supplied and an appropriate crimping tool.
Wiring of the main conductor: Respect the ATEX (T5) classification. Strip the conductor by 46mm. Use the correct crimp die (e.g., NFC 20-130 / VDE 0220) — hexagonal crimping is recommended. Apply torque approx. 70 N·m. Maintain the rear of the contact with a 24mm key while tightening.
Connector assembly: Assemble handles using supplied gaskets/screws and tighten the cable gland with an appropriate tool. To achieve IP65/IP66 for an interlocked connector, use a cable incorporating the two pilot wires required for the interlock (or an ATEX cable gland solution allowing the main cable plus the two pilot cables).
Metal inclined sleeve: Respect air/creepage distances for main and auxiliary circuits. Connect the metal inclined sleeve to earth.
Watertightness & identification: Do not forget the colour-coded ring at the rear of the inlet/socket-outlet. Ensure caps are reassembled after use. For IP65/IP66, assemble the socket-outlet/connector cap with its slot facing the protruding finger.
Operation (summary):
SPeX Single Pole Range (EN) (PDF)
Installation / Instructions (PDF)
Dimensions (PDF)
ATEX Certificate (PDF)
IECEx Certificate (PDF)
CSA Certificate (PDF)
↑ BACK TO TOP
| Category | ATEX Plugs, Sockets & Connectors |
|---|
| Specification | SPeX |
| Rated Current (with wiring according to standard) | According to category and cable |
| Maximum Voltage AC | 1,000V |
| Maximum Voltage DC | 1,500V |
| Short-Circuit Current (Icc) | 20kA during 250ms |
| IP Protection (Lid Closed) | IP65 / IP66 |
| IP Protection (Connected Plug) | IP65 / IP66 |
| Shock Resistance | IK08 |
| Ambient Temperature | See ATEX classification table |
| Wiring (Min–Max) | See ATEX classification table |
| Keying Positions | Mechanical (5) and visual |
| Protection Mode | e |
| ATEX Zones | 1 & 2 (Gas), 21 & 22 (Dust) |
| Number of Operations | 2,000 |
| Pre-wired Pilot Circuit | 6A / 250V |
| Cable Cross Section | -20°C ≤ Ta ≤ +40°C (G/D) T5 / T56°C | -20°C ≤ Ta ≤ +40°C (G/D) T6 / T56°C | -20°C ≤ Ta ≤ +60°C (G/D) T5 / T76°C |
| 70mm² | 290A | 235A | 235A |
| 95mm² | 415A | 335A | 335A |
| 120mm² | 456A | 376A | 376A |
| 150mm² | 493A | 415A | 415A |
| 185mm² | 530A | 450A | 450A |
| 240mm² | 570A | 497A | 497A |
| 300mm² | 620A | 540A | 540A |
| 400mm² | 680A | 600A | 600A |
Tell us your quantity and requirements — we reply within one business day.
ATEX Plugs, Sockets & ConnectorsProduct Code: 2514015
ATEX Plugs, Sockets & ConnectorsProduct Code: 2518013
The range of ATEX Plugs according to – the section outlines the complete range of hazardous area plugs and sockets certified by ATEX to the Ex e Explosion Proof explosion protection concept.
Share your specifications and quantities. Our team will review your request and come back with sourcing options and a quotation.