Mining CablesCables
AS/NZS 2802 Type 455 Mining Cable
General use cable for mines (except for underground coal mines). Suitable to trailing and reeling due to its’ smaller dimensions.
3.3/3.3 kV, 6.6/6.6 kV, 11/11 kV, 22/22 kV

Used far supplying excavating, crushing machines and equipment.
Used far supplying excavating, crushing machines and equipment.
| Rated voltage | 1900/3300 V |
|---|---|
| Conductor | Electrolytic, stranded, tinned copper wire IEC 60228 Class 5 |
| Insulation | EPR |
| Outer sheath | Heavy duty chloroprene outer sheath. |
| Layup | Cores are /aid up over a crad/e without contacting each other. |
| Bedding | Rub ber based bedding compound. |
| Armour | Galvanized stee/ pliab/e armour. |
| Related standards | MGM112/1984 |
| Test voltage | 7,5 kV |
| Cross Section | 3×35+25 | 3×50+25 | 3×50+35 | 3×70+50 | 3×95+70 | 3×120+70 | |
|---|---|---|---|---|---|---|---|
| Phase Conductors | |||||||
| Number and cross section | mm2 | 3×35 | 3×50 | 3×50 | 3×70 | 3×95 | 3×120 |
| lnsulation thickness | mm | 3.0 | 3.0 | 3.0 | 3.0 | 3.0 | 3.0 |
| Earth Conductor | |||||||
| Number and cross section | mm2 | 1×25 | 1×25 | 1×35 | 1×50 | 1×70 | 1×70 |
| Stranding | mm | 196/0,40 | 196/0,40 | 276/0,40 | 396/0,40 | 360/0,50 | 360/0,50 |
| Conductor diameter | Nam.mm | 6.75 | 6.75 | 8.00 | 9.75 | 11.90 | 11.90 |
| lnsulation thickness | mm | 3.8 | 5.0 | 4.4 | 4.5 | 4.6 | 4.9 |
| Cable details | |||||||
| Radial thickness of inner sheath | mm | 2.5 | 3.8 | 3.8 | 3.8 | 5.0 | 5.0 |
| Min. inner sheath diameter | mm | 44.3 | 51.3 | 51.3 | 56.4 | 63.8 | 67.5 |
| Max. inner sheath diameter | mm | 46.8 | 53.3 | 53.3 | 59.4 | 66.8 | 71.3 |
| Size of armour | mm | 7/0,90 | 7/0,90 | 7/0,90 | 7/0,90 | 7/1,25 | 7/1,25 |
| Radial thickness of outer sheath | mm | 5.3 | 5.4 | 5.4 | 6.3 | 6.8 | 7.2 |
| Min. overall diameter | mm | 60.3 | 66.9 | 66.9 | 74.4 | 84.9 | 89.4 |
| Max. overall diameter | mm | 64.1 | 70.9 | 70.9 | 78.4 | 89.2 | 93.7 |
| Min. bending radius | mm | 770 | 851 | 851 | 941 | 1,071 | 1,125 |
| Appx. cable weight | kg/km | 7,050 | 8,750 | 8,900 | 10,200 | 15,950 | 18,700 |
| Copper weight | kg/km | 1,250 | 1,680 | 1,780 | 3,570 | 4,160 | 5,950 |
| Electrical details | |||||||
| “Continuous current rating at 25°C Ambient” | A | 135 | 170 | 170 | 205 | 250 | 295 |
| Max. DC resistance at 20°C | |||||||
| Phase conductors | Ω/km | 0.565 | 0.393 | 0.393 | 0.277 | 0.210 | 0.164 |
| Earth conductor | Ω/km | 0.795 | 0.795 | 0.565 | 0.393 | 0.277 | 0.277 |
| Armour | Ω/km | 0.92 | 0.79 | 0.79 | 0.50 | 0.38 | 0.30 |
Tell us your quantity and requirements — we reply within one business day.
Mining CablesGeneral use cable for mines (except for underground coal mines). Suitable to trailing and reeling due to its’ smaller dimensions.
Mining CablesGeneral use cable for mines (except for underground coal mines). It has smaller dimensions but strong structure.
Mining CablesGeneral use cable for mines (except for underground coal mines)
Share your specifications and quantities. Our team will review your request and come back with sourcing options and a quotation.