MGM 112 Type E2, Type E4, Type E5 Mining Cable

Used for supplying excavating, crushing machines and equipment.

Rated voltage660/1100 V
ConductorElectrolytic, stranded, tinned copper wire IEC 60228 Class 5
InsulationEPR
Outer sheathHeavy duty chloroprene outer sheath.
  • Quoted to your quantity
  • Documentation on request
  • International delivery

Product Overview

Used for supplying excavating, crushing machines and equipment.

Technical Specifications

Rated voltage660/1100 V
ConductorElectrolytic, stranded, tinned copper wire IEC 60228 Class 5
InsulationEPR
Outer sheathHeavy duty chloroprene outer sheath.
LayupCores are laid up over a cradle without contacting each other (except for Tip E2).
BeddingRubber based bedding compound.
ArmourGalvanized steel pliable armour.
Related standardsMGM 112/1984
Test voltage3 kV
Cross Section2×44×2,54×44×64×104×164×254×354×504×70
MGM 112 TYPE E2 E4
Conductors
Conductor diameterNom. mm2.602.102.703.304.405.507.108.4010.1011.90
Insulation thicknessmm1.01.41.41.51.51.51.61.61.71.7
Cable details
Radial thickness of inner sheathmm2.02.02.02.52.52.52.52.52.53.8
Size of armourmm7/0,457/0,457/0,457/0,707/0,707/0,707/0,707/0,907/0,907/0,90
Radial thickness of outer sheathmm2.52.52.53.83.83.84.34.75.15.7
Min. overall diametermm23.926.227.736.738.841.546.151.056.164.8
Max. overall diametermm26.428.630.138.841.044.049.856.161.871.4
Min. bending radiusmm264286301388410440498561618714
Appx. cable weightkg/km9501.281.452.452.93.64.455.657.359.5
Copper weightkg/km801001602403906209601.351.922.69
Electrical details
“Continuous current rating at 25°C Ambient”A282837466385110135170205
Max. DC resistance at 20°C
Phase ConductorΩ /km5.098.215.093.391.951.240.7950.5650.3930.277
Cross section4×954×1204×1505×45×65×105×16
TYPE E4 E5
Conductors
Number and cross sectionmm24×954×1204×1505×45×65×105×16
Strandingmm475/0,50608/0,50756/0,5056/0,3084/0,3080/0,40126/0,40
Conductor diameterNom. mm13.9015.8017.002.603.304.405.50
Insulation thicknessmm2.02.22.31.41.51.51.5
Cable details
Radial thickness of inner sheathmm3.85.05.02.02.02.52.5
Size of armourmm7/0,907/1,257/1,257/0,457/0,507/0,707/0,70
Radial thickness of outer sheathmm6.33.87.32.53.83.83.8
Min. overall diametermm74.983.891.431.038.042.446.5
Max. overall diametermm78.689.095.332.340.045.048.9
Min. bending radiusmm786890953323400450489
Appx. cable weightkg/km10.9515.618.51.752.93.94.8
Copper weightkg/km3.654.615.76200290480770
Electrical details
“Continuous current rating at 25°C Ambient”A25029532028466385
Max. DC resistance at 20°C
Phase ConductorΩ /km0.2100.1640.1325.093.391.951.24

Certifications / Standards

  • ALSZ