Industrial CablesUL Style 1015 Industrial Cable
Fixed installation for power, control and lighting in both and safe areas applications.

Especially suitable for connections of short circuit and grounding. They are used in railway vehicels, buses, switch cabinets, continuously operating installations, pipes, trays and in closed electrical trays. These cables…
Especially suitable for connections of short circuit and grounding. They are used in railway vehicels, buses, switch cabinets, continuously operating installations, pipes, trays and in closed electrical trays. These cables can be used as connection power cable in transformer substations.
| Rated voltage | 600/1000 V – 1800/3000 V – 3600/6000 V (U0/U) |
|---|---|
| Conductor | Electrolytic annealed, class 5 stranded tinned copper wires |
| Insulation | 3GI3 type cross-linked elastomeric compound (VDE 0207 – Part 20) |
| Sheath | 5GM3 type cross-linked elastomeric compound (VDE 0207 – Part 21) |
| Operating temperature — in flexing use | -25°C to +90°C |
| Operating temperature — in fixed use | -40°C to +90°C |
| Operating temperature — max. conductor operating temp. | 90°C |
| Separator | A suitable tape may be applied over the conductor, with semi-conductive layer for 3,6/6 kV |
| Color | Black |
| AC test voltage | 4 kV / 6kV / 11 kV |
| Conductor short-circuit temp. | 250°C (Max. 5 sec) |
| Min. installation temp. | -25°C |
| Min. bending radius | VDE 0298-3 Tab.3 |
| Current carrying capacities | VDE 0298-4 Tab. 15 |
| Cross Section (mm²) | Nominal Overall Diameter (mm) | Approximate Weight (kg / km) | Min.Bending Radius (fixed installation) (mm) | Max. Resistance of Conductors at 20°C (ohm / km) |
|---|---|---|---|---|
| NSGAFÖU 0,6/1kV | ||||
| 1×1,5 | 4,80 | 36 | 14 | 13,70 |
| 1×6 | 6,60 | 88 | 20 | 3,39 |
| 1×10 | 8,10 | 140 | 24 | 1,95 |
| 1×16 | 9,10 | 197 | 27 | 1,24 |
| 1×25 | 11,40 | 300 | 34 | 0,795 |
| 1×35 | 12,70 | 404 | 51 | 0,565 |
| 1×50 | 14,60 | 551 | 58 | 0,393 |
| 1×70 | 16,50 | 764 | 66 | 0,277 |
| 1×95 | 18,45 | 981 | 74 | 0,21 |
| 1×120 | 20,15 | 1223 | 81 | 0,164 |
| 1×150 | 21,95 | 1504 | 88 | 0,132 |
| 1×185 | 24,65 | 1840 | 99 | 0,108 |
| 1×240 | 27,95 | 2449 | 112 | 0,0817 |
| 1×300 | 30,75 | 3004 | 123 | 0,0654 |
| NSGAFÖU 1,8/3 kV | ||||
| 1×1,5 | 5,80 | 48 | 17 | 13,70 |
| 1×2,5 | 6,20 | 60 | 19 | 8,21 |
| 1×4 | 6,70 | 77 | 20 | 5,09 |
| 1×6 | 7,20 | 97 | 22 | 3,39 |
| 1×10 | 8,70 | 151 | 26 | 1,95 |
| 1×16 | 9,70 | 210 | 29 | 1,24 |
| 1×25 | 12,60 | 333 | 50 | 0,795 |
| 1×35 | 13,50 | 428 | 54 | 0,565 |
| 1×50 | 15,00 | 565 | 60 | 0,393 |
| 1×70 | 16,90 | 780 | 68 | 0,277 |
| 1×95 | 19,25 | 1015 | 77 | 0,21 |
| 1×120 | 20,95 | 1261 | 84 | 0,164 |
| 1×150 | 22,75 | 1545 | 91 | 0,132 |
| 1×185 | 25,05 | 1863 | 100 | 0,108 |
| 1×240 | 28,38 | 2475 | 114 | 0,0817 |
| 1×300 | 31,15 | 3033 | 125 | 0,0654 |
| NSGAFÖU 3,6/6 kV | ||||
| 1×1,5 | 8,70 | 84 | 26 | 13,70 |
| 1×2,5 | 9,10 | 98 | 27 | 8,21 |
| 1×4 | 9,60 | 117 | 29 | 5,09 |
| 1×6 | 11,10 | 164 | 33 | 3,39 |
| 1×10 | 11,60 | 200 | 35 | 1,95 |
| 1×16 | 13,10 | 278 | 52 | 1,24 |
| 1×25 | 15,40 | 394 | 62 | 0,795 |
| 1×35 | 16,40 | 496 | 66 | 0,565 |
| 1×50 | 17,90 | 639 | 72 | 0,393 |
| 1×70 | 22,40 | 987 | 90 | 0,277 |
| 1×95 | 24,60 | 1233 | 98 | 0,21 |
| 1×120 | 23,50 | 1335 | 94 | 0,164 |
| 1×150 | 24,90 | 1602 | 100 | 0,132 |
| 1×185 | 26,80 | 1901 | 107 | 0,108 |
| 1×240 | 30,50 | 2539 | 122 | 0,0817 |
| 1×300 | 33,10 | 3088 | 132 | 0,0654 |
Tell us your quantity and requirements — we reply within one business day.
Industrial CablesFixed installation for power, control and lighting in both and safe areas applications.
Industrial Cables3GKW MM Flex Industrial Cable for industrial applications. Construction: Tinned fine copper strands (class 5 acc. to IEC 60228); Cross-linked elastomeric special compound; Cross-linked elastomeric special compound.
Industrial Cables3GKW M Industrial Cable for industrial applications. Construction: Electrolytic tinned, class 5 stranded copper wires (Iec 60228); Halogen‐free. heat resistant. cross‐linked elastomeric special compound (Requirements based on type El 109…
Share your specifications and quantities. Our team will review your request and come back with sourcing options and a quotation.