Resistance Heating Cable | Eltherm ELK-AG-L 3.4 | Factory Terminated Trace Heating Cable

Eltherm ELK-AG-L resistance heating cables and tapes provide process temperature maintenance and frost protection to vessels, pipes, valves and small components up to 260° Celsius.

CategoryHeat Tracing Cables & Systems
  • Quoted to your quantity
  • Documentation on request
  • International delivery

Product Overview

Eltherm ELK-AG-L resistance heating cables and tapes provide process temperature maintenance and frost protection to vessels, pipes, valves and small components up to 260° Celsius.

Please Note: This product has been discontinued. Please Contact our team for an alternative!

Specification

  • Nominal Supply Voltage : 230V
  • Maximum Output : 25 w/m
  • Maximum Operating Temperature : 260ºC
  • Minimum Installation Temperature : -60° Celsius
  • Heating Conductor Diameter: 4.1-4.8mm
  • Minimum Heater Cable Bend Radius : 2.5mm x outer diameter
  • Insulation : PTFE
  • Protective Braid: Nickel-plated Copper
  • Outer Jacket: PTFE
  • Cold Lead Length (Both Ends) : 1.2m without plug
  • Moisture Proof : Yes
  • Protection Class: I
  • Manufactured According To : DIN VDE 0253, EN 62395-1
  • VDE Mark Approval: 40001594
  • Heating Cable Type : Resistance Heating Cable

resistance Heating Cable – Eltherm ELK-Ag-l Maximum heating circuit length

Other lengths of ELK-AG-L resistance heating cables are available upon request.
Resistance Tolerance: +/- 5%
All output figures are nominal values at +20ºC
Lengths tolerance ± 2%, max ± 0.25m

Eltherm ELK-AG-L – Applications

  • Heat tracing on tanks
  • Heat tracing on vessels
  • Heat tracing on filters
  • Heat tracing on satellite dishes
  • Heat tracing on hoppers
  • Pipes, valves and pumps
  • Automotive
  • Tank containers
  • IBC’s
  • Heating hoods

Eltherm ELK-AG-L resistance heating cables provide temperature maintenance and frost protection to pipework and mechanical services in all industries – typical applications include industrial and hazardous area heating of process pipework, instrument lines and storage tanks to maintain viscosity or prevent frost damage as an integral work-task of plant Winterisation.

Resistance Heating Cables

Eltherm resistance heating cables are manufactured from a high-resistance heating conductor, PTFE insulated with protective braid and fluoropolymer outer jacket. Powered at specific voltage the resistance heat generated by the conductors provides electrical trace heating to pipes and vessels. Resistance heating cables will “burn-out” if overlapped unlike self-regulating trace heating cables.

High temperature resistance heating cables insulated with glass fibre provide electrical heating up to 800° Celsius.

Technical Specifications

CategoryHeat Tracing Cables & Systems
DesignationHeated LengthNominal Output (W) Temperature Max. 100°CEltherm Order CodeNominal Output (W) Temperature Max. 150°CEltherm Order CodeNominal Output (W) Temperature Max. 200°CEltherm Order Code
ELK-AG-L 3.43.4 m780135031520135032260135033