Rotronic CF1 CO2 Gas Measurement Transmitter (+Humidity & Temperature)

Rotronic CF1 CO2 gas measurement transmitter is a carbon dioxide measurement instrument with integrated humidity and temperature measurement.

BrandRotronic
CategoryProcess Instrumentation
  • Quoted to your quantity
  • Documentation on request
  • International delivery

Product Overview

Rotronic CF1 CO2 gas measurement transmitter is a carbon dioxide measurement instrument with integrated humidity and temperature measurement.

The Rotronic CF1 features the proven Hygromer IN1 sensor and offers un-rivalled performance and accuracy with an elegant design that fits in many industries and applications.

Altering the scaling is simple with the Rotronic SW21/HW4 software and the measurement transducer can be adjusted and calibrated in the humidity and CO2 ranges.

Rotronic CF1 CO2 Gas Measurement Transmitter (+Humidity & Temperature) Product Features

  • Measures CO2, relative humidity, and temperature
  • Hygromer® IN-1 humidity sensor
  • Adjustable at 35 %RH or 80 %RH
  • Scalable analog voltage or current outputs
  • Single-relay output
  • Small size
  • Compatible with HW4 software
  • Three programmable LEDs

Rotronic – Carbon Dioxide GAS Measurement for Ventilation Monitoring

Rotronic devices including transmitters, data loggers and hand held instruments are used for regulating ventilation in living areas, offices, classrooms, cinemas, hospitals and also for measuring CO2 pollution in garages, tunnels and logistics facilities. Rotronic carbon dioxide gas measurement instruments monitor indoor air quality (IAQ) safeguarding the health, productivity and comfort of occupants.

Rotronic Measurement

View the current Rotronic catalogue :

Technical Specifications

BrandRotronic
CategoryProcess Instrumentation
ParametersHumidity/temperature and CO2
DimensionsType R: 131 x 86 x 32 )H,W,D) mm Type S: 120 x 86 x 32 )H,W,D) mm
WeightType R: 115g, Type S: 135g
Range of applicationElectronics: 0 .. 50 °C Measuring range probe dependent 0 .. 100 %RH, non-condensing
Accuracy At 23 ± 5°c<3 % RH (10..90 %RH) / ± 0.3, ± 1 K type S with display 0 .. 2000 ppm: ± 40 ppm ± 3 % of measured value 0 .. 5000 ppm: ± 10 % of measured value
Measurement principleInfrared (NDIR)
Measurement ranges0..2000 ppm or 0..5000 ppm
Adjustment points0, 400 ppm and 35, 80 %RH
Pressure dependency+1.6 % reading per kPa
Power supply/power consumption12..28 VAC / 15..40 VDC 86.5 mA
Long-term stability< 1.5 %RH per year
Humidity sensorROTRONIC HYGROMER® IN-1
Standard temperature scale0…50 °C or 0…100 °F
Temperature sensorThermistor
Measurement principleInfrared (NDIR)
Measurement range0..2000 ppm or 0..5000 ppm
Precision at 23 °C ± 5 K 0 .. 2000 ppm 0 .. 5000 ppm± 40 ppm ± 3 % of measured value ± 10 % of measured value
Adjustment points400 ppm
Response time<3 min diffusion time
Pressure dependence+ 1.6 % of read-off per kPa