Self Regulating Heat Tracing | Eltherm ELSR-FHP ATEX Heat Tracing Cable (Up to 110 Degrees Celsius)

Eltherm ELSR-FHP is a versatile self-regulating heat tracing cable that provides process temperature maintenance and frost protection to pipework, instrument lines, tanks and drums up to 110° Celsius – with IECEx and…

CategoryHeat Tracing Cables & Systems
  • Quoted to your quantity
  • Documentation on request
  • International delivery

Product Overview

Self Regulating HeaT tRACING Cables

Eltherm ELSR-FHP is a versatile self-regulating heat tracing cable that provides process temperature maintenance and frost protection to pipework, instrument lines, tanks and drums up to 110° Celsius – with IECEx and ATEX Certification Eltherm ELSR-N heat tracing cables are suitable for Zone 1 and Zone 2 hazardous areas.

The self-regulating technology allows the heating cable to increase or decrease its heat output based on the ambient temperature, providing energy-efficient operation and preventing overheating. ELSR-FHP is suitable for use in various industrial applications where maintaining consistent temperatures is critical for process integrity and safety including:

  • Freeze prevention
  • Silos, vessels, tanks
  • Cryogenic Storage Tanks

Our Team of Trained Sales Engineers are available to advise and support your ATEX heat tracing enquiries – this includes design and supply of complex multi-kilometre, major-project systems to custom heat trace cable kits for the protection of winterisation against plant and factory facilities.

ELTHERM ELSR-FHP heat tracing CABLE – SPECIFICATION

Eltherm ELSR-FHP self-regulating trace heating wattages per metre at 5°C – 23, and 38 watts.

  • Nominal Supply Voltage : 230v
  • Maximum Cable Exposure Temperature – Power off: 110ºC, 80ºC
  • Maximum Cable Exposure Temperature – Power on: 80ºC, 65ºC
  • Minimum Installation Temperature : -45° Celsius
  • Minimum Heater Cable Bend Radius : 50mm
  • Heater Cable Outer Jacket: Fluoropolymer
  • Bus Wire: Nickel plated copper
  1. Bus wire – Nickel plated Copper
  2. Self-regulating heating element
  3. Insulation
  4. Protection: Protective braid (Cu, tin plated)
  5. Outer jacket – Fluoropolymer

Eltherm ELSR-FHP self-regulating heating cables are available in the BO design. The BO version of the ELSR-FHP heating cable has a protective tin-plated copper braid to adapt to low-temperatures and medium temperature applications.

Hazardous Area Classifications

Heat Tracing Classification:

  • II 2G Ex e IIC Gb
  • II 2D Ex tb IIIC TX Db

Hazardous Area Certification:

  • 14ATEX1653X
  • IECEx EPS 14.0021U

Temperature Class: T5

Eltherm ELSR-FHP Heating Cable Benefits

  • Highly robust
  • Suitable for harsh installed environment
  • Flexible mounting
  • Waterproof

Eltherm ELSR-FHP heating cables provide process temperature maintenance and frost protection to pipework, instrument lines, tanks and drums up to 110° Celsius – with IECEx and ATEX Certification Eltherm ELSR-N trace heating cables are suitable for Zone 1 and Zone 2 hazardous areas. Typical applications include heating process pipework, instrument lines and storage tanks to maintain viscosity or prevent frost damage as an integral work-task of plant Winterisation.

Eltherm ELSR-FHP cables utilise cold-applied installation components to complete the trace heating system – no requirement for “hot-working” permit applications in potentially explosive atmospheres, including Zone 1 and Zone 2 hazardous areas.

elsr-fhp heating Circuit Length

Contact our team for technical guidance, heat loss calculations for pipework systems and optimum specification of the correct trace heating cable for your application.

ELSR-N Heating circuit length

*1 Heating circuit lengths on the following conditions:

  • 230 V nominal voltage
  • Delayed action circuit breakers (C-characteristic) with 110 % max. load
  • Maximum 10 % line voltage drop on heating cable bus wire
  • Power connection to one heater end
  • In certain installation situations, the heating circuit length may vary. Please contact our team

Eltherm ELSR-N HEATer CABLES

Eltherm video providing a step-by-step termination of ELSR-N heater cable using a EL-ECN termination kit.

Self-Regulating heat tracing System

A Trace Heater
B Power Connection Kit
C End Termination Kit
D Junction Box
E Pipe Mounting Bracket
F Fasteners and Self-adhesive Tapes, Foils
G Insulation Bushing
H Warning Sign
I Temperature Controller
J Temperature Sensor

Technical Specifications

CategoryHeat Tracing Cables & Systems
Eltherm ELSR-FHP Heater CableNominal OutputCable Dimensions (mm)Cable Weight Approx (g/m)
ELSR-FHP-23Approx 23 w/m at 5ºC (in 25mm / 1″ conduit)14 x 5.5155
ELSR-FHP-38Approx 38 w/m at 5ºC (in 25mm / 1″ conduit)14 x 5.5155
Switch on temperature [°C]Nominal fuse rating [A]Heating circuit length*1 [m]
ELSR-FHP-23ELSR-FHP-38
-51030.023.0
1648.036.0
2060.045.0
2575.072.0
3297.091.0
40121.021.0
-151023.034.0
1637.043.0
2046.054.0
2557.068.0
3274.085.0
4092.085.0

Request Information About This Product

Tell us your quantity and requirements — we reply within one business day.

Related Products

Have a product requirement?

Share your specifications and quantities. Our team will review your request and come back with sourcing options and a quotation.