SICK GMS800 | Extractive Gas Analyser For Process & Emission Monitoring

Gas analysis for process and emission monitoring

BrandSICK
CategoryGas Detection
  • Quoted to your quantity
  • Documentation on request
  • International delivery

Product Overview

Sick GMS800

Gas analysis for process and emission monitoring

The GMS800 is an extractive gas analyser manufactured by SICK which can measure over 60 different gas compounds and is used for process and emission monitoring.

SICK GMS800 is typified by its modular design: 6 analysing modules, one gas module, I/O modules and an operating unit. Standardised 19″ racks can be used for economic system integration. Wall mounting enclosures with an ATEX approval for use in hazardous areas can also be used for applications within rough industrial environments.

Equipped with modern software, the GMS800 comes with the required interfaces for remote control via networks through to the connection to a process control system.

Typical Applications for SICK GMS800 Gas Analysers

  • Emission monitoring according to EN 15267 and process gas measurements, including in potentially explosive atmospheres
  • Emission monitoring of very low concentrations
  • Measurement of smallest concentrations of NO, NO2, and SO2
  • NOx monitoring by direct measurement of NO and NO2
  • Measurement of sulphur compounds in process gases
  • CO monitoring for explosion protection
  • Measurement of smallest concentrations in hydrogen or hydrocarbons

Features

  • Approved according to EN 15267 and EN 14181
  • Installations in Non-Ex-areas and Ex-areas (Zone 1 and 2 according to ATEX) possible
  • Minimum service and maintenance work as well as easy reconditioning of existing installations due to modular design
  • Adjustment without test gases via optional adjustment unit
  • Minimal influence of ambient temperature through thermostatic controlled modules
  • Reliable measuring results by proven measurement technology
  • Easy maintenance and repair due to replacement of complete assemblies or modules
  • 6 different analyser modules: DEFOR (NDUV, UVRAS), MULTOR (NDIR), OXOR-E (electrochemical O2), OXOR-P (paramagnetic O2), THERMOR (TC), and UNOR (NDIR)
  • 4 different types of enclosures
  • Gas module with sample gas pump and/or control sensors
  • New enclosure type for easy and quick integration in analyser systems
  • Remote diagnosis via Ethernet with SOPAS ET software

Technical SPECIFICATION

Please note: The exact device specifications and performance data of the product may deviate from the information provided here, and depend on the application in which the product is being used and the relevant customer specifications.

FOR EXPLOSIVE ATMOSPHERES & Hazardous Areas

Key Product Categories: Control Panels | Plugs & Sockets | Isolators | Enclosures & Junction Boxes | Lighting | Control Stations | Motor Starters | Heat Trace Cables & Systems | Gas Detection & Detectors | Fire Detection & Detectors | Heat Detectors | Electrical Heating & Heaters

Also Process Instrumentation Products: Ashcroft Pressure Gauges | ASCO Valves | Katronic Flow Meters | KROHNE Flow Meters | VEGA Level Sensors | Rotronic Temperature & Humidity Sensors | SIKA Pressure Gauges

Technical Specifications

BrandSICK
CategoryGas Detection
Measured ValuesAr, CH4, CH3OH, C2H2, C2H2F4, C2H4, C3H6, C3H8, C4H6, Cl2, CO, CO2, COCl2, COS, CS2, H2, H2S, He, NH3, NO, N2O, NO2, O2, SF6, SO2, other components on request
Performance Tested MeasurandsCH4, CO, CO2, NO, NO2, O2, SO2
Gas Flow Rate30 l/h … 60 l/h
Sample Gas TemperatureAnalyser Inlet: 0 °C … +45 °C
Process PressureHosed Gas Lines: –200 hPa … 300 hPa Tubed Gas Lines: –200 hPa … 1,000 hPa
Process Gas HumidityNon-condensing
Dust LoadFree of dust and aerosols
Ambient Temperature+5 °C … +45 °C
Storage Temperature–20 °C … +70 °C
Ambient Pressure700 hPa … 1,200 hPa
Geographical Altitude+ 2,500 m (above mean sea level)
Ambient Humidity20 % … 90 % Relative humidity; non-condensing
Electrical SafetyCE
Description19″ rack enclosure with 4 rack units, for integration in cabinets
Electrical SafetyCE
Enclosure RatingIP40
Dimensions (W x H x D)483 mm x 178 mm x 388 mm
Weight9 kg … 20 kg Depending on configuration
Power SupplyVoltage: 93 … 132 V AC / 186 … 264 V AC / 210 … 370 V AC Frequency: 47 … 63 Hz Power Consumption: ≤ 300W
Sample Gas ConnectionsPVDF bulkhead fitting: for hose 6 x 1 mm
Auxiliary gas ConnectionsFor purge gas or flowing reference gas: option
OptionsGas connections: Swagelok 6 mm or Swagelok 1/4″
Description19″ rack enclosure with 4 rack units, for usage with separate control unit (BCU), for integration in cabinets
Electrical SafetyCE
Enclosure RatingIP40
Dimensions (W x H x D)483 mm x 178 mm x 388 mm
Weight9 kg … 20 kg Depending on configuration
Power SupplyVoltage: 93 … 132 V AC / 186 … 264 V AC / 210 … 370 V AC Frequency: 47 … 63 Hz Power Consumption: ≤ 300W
Sample Gas ConnectionsPVDF bulkhead fitting: for hose 6 x 1 mm
Auxiliary gas ConnectionsFor purge gas or flowing reference gas: option
OptionsGas connections: Swagelok 6 mm or Swagelok 1/4″
Phase-outThis system component will be phased out soon
DescriptionWall-mounting enclosure with gas-tight separated analysing and electronic units, purgeable separately
Ex ApprovalsATEX: II 3G Ex nR II T6
Electrical SafetyCE
Enclosure RatingIP65/NEMA 4x
Dimensions (W x H x D)550 mm x 740 mm x 289 mm
Weight20 kg … 57 kg Depending on configuration
Power SupplyVoltage: 93 … 132 V AC / 186 … 264 V (Not with pressurized apparatus: 210 … 370 V) Frequency: 47 … 63 Hz Power Consumption: ≤ 300 W
Sample Gas ConnectionsPVDF bulkhead fitting: for hose 6 x 1 mm
Auxiliary Gas ConnectionsFor purge gas or flowing reference gas: option
OptionsGas connections: Swagelok 6 mm or Swagelok 1/4″ Integrated flame arrestors for gas inlet and outlet Intrinsically safe outputs for measured values
DescriptionFlame-proof enclosure for use in Ex-zone 1 areas
Ex ApprovalsIECEx: Ex db eb [ia] IIC T6 ATEX: II 2G Ex db eb [ia] IIC T6 Gb II 2G Ex db eb IIC T6 Gb
Electrical SafetyCE
Enclosure RatingIP65
Dimensions (W x H x D)790 mm x 590 mm x 353 mm
Weight140 kg … 150 kg Depending on configuration
Power SupplyVoltage: 93 … 132 V AC / 186 … 264 V AC / 210 … 370 V AC Frequency: 47 … 63 Hz Power Consumption: ≤ 300 W
Sample Gas ConnectionsInside thread G1/4″
Auxiliary Gas ConnectionsFor purge gas or flowing reference gas: option
OptionsGas connections: Swagelok 6 mm or Swagelok 1/4″
DescriptionClosed sheet steel housing for wall mounting for use indoors
Ambient Temperature+5 °C … +45 °C
Storage Temperature–10 °C … +70 °C
Ambient Humidity10 % … 95 % Non-condensing
Ex ApprovalsIECEx GMS841: Ex nA nC IIC T4 Gc GMS841: Ex nA nC [ia Ga] IIC T4 Gc ATEX GMS841: II 3G Ex nA nC IIC T4 Gc GMS841: II 3G Ex nA nC [ia Ga] IIC T4 Gc NEC/CEC (US/CA) GMS842: Class I, Division 2, Group A, B, C, D T4 GMS842: Class I, Zone 2 GMS842: Ex nA nC IIC T4 Gc GMS842: Ex nA nC [ia Ga] IIC T4 Gc GMS842: AEx nA nC IIC T4 Gc GMS842: AEx nA nC [ia Ga] IIC T4 Gc
Electrical SafetyCE
Enclosure RatingIP66/NEMA 4x
Dimensions (W x H x D)522 mm x 475 mm x 478 mm
Weight≤ 30 kg depending on configuration
Power SupplyVoltage: GMS840: 85 … 264 V AC Frequency: 47 … 63 Hz Current Consumption: ≤ 10 A Power Consumption: ≤ 300 W depending on configuration
Sample Gas ConnectionsInside thread G1/4″: for screw-in fittings Swagelok 6 mm: stainless steel, for metal tube Swagelok 1/4″: stainless steel, for metal tube PVDF compression fitting: for hose 6 x 1 mm
DescriptionUV gas analyser for simultaneous measurement of up to 3 gas components
Measurement PrinciplesNDUV spectroscopy, UVRA spectroscopy
Measuring RangesCl2: 0 … 125 ppm / 0 … 100 Vol.-% COS: 0 … 250 ppm / 0 … 100 Vol.-% CS2: 0 … 50 ppm / 0 … 30 Vol.-% H2S: 0 … 25 ppm / 0 … 100 Vol.-% NH3: 0 … 50 ppm / 0 … 100 Vol.-% NO: 0 … 10 ppm / 0 … 100 Vol.-% NO2: 0 … 125 ppm / 0 … 100 Vol.-% NO2(*): 0 … 50 ppm / 0 … 100 Vol.-% SO2: 0 … 25 ppm / 0 … 100 Vol.-% SO2(*): 0 … 10 ppm / 0 … 100 Vol.-% (*) NO2, SO2: Smallest measuring range with daily adjustment of zero point and operation in an air-conditioned environment with temperature stability of ± 2 °C
Certified Measuring RangesNO: 0 … 50 mg/m³ / 0 … 1,000 mg/m³ / 0 … 2,000 mg/m³ NO2: 0 … 50 mg/m³ / 0 … 500 mg/m³ SO2: 0 … 75 mg/m³ / 0 … 287 mg/m³ / 0 … 2,000 mg/m³
Response Time (t90)4 s Typical at 60 l/h, depending on cell length and gas flow
Sensitivity Drift≤ 1 %: of measuring range full scale per week
Zero Point Drift≤ 1 %: of measuring range full scale per week Measuring ranges smaller than 2 x smallest measuring range: ≤ 2 %: of measuring range full scale per week
ConformitiesApproved for plants requiring approval – 2001/80/EC (13. BImSchV) 2000/76/EC (17. BImSchV) 27. BImSchV TA-Luft (Prevention of Air Pollution) EN 15267 EN 14181 MCERTS
Corrective FunctionsManual or automatic adjustment with test gases or adjustment cell
Test FunctionsSelf test & fault diagnosis
DescriptionMulti-component NDIR analyzer for continuous measurement of up to 3 IR-absorbing gases and H2O for internal interference sensitivity correction
Measurement PrinciplesNDIR spectroscopy
Measuring RangesCH4: 0 … 400 ppm / 0 … 100 Vol.-% CO: 0 … 160 ppm / 0 … 100 Vol.-% CO2: 0 … 100 ppm / 0 … 100 Vol.-% NO: 0 … 190 ppm / 0 … 100 Vol.-% SO2: 0 … 90 ppm / 0 … 100 Vol.-%
Certified Measuring RangesCH4: 0 … 286 mg/m³ / 0 … 500 mg/m³ CO: 0 … 200 mg/m³ / 0 … 2,000 mg/m³ CO2: 0 … 25 Vol.-% NO: 0 … 250 mg/m³ / 0 … 2,500 mg/m³ SO2: 0 … 250 mg/m³ / 0 … 2,000 mg/m³
Response Time (t90)≤ 25 s Typical at 60 l/h, depending on cuvette length, gas flow and number of measuring components
Sensitivity Drift≤ 1 %: of measuring range full scale per week
Zero Point Drift≤ 1 %: of measuring range full scale per week Measuring ranges smaller than 2 x smallest measuring range: ≤ 2 %: of measuring range full scale per week
ConformitiesApproved for plants requiring approval – 2001/80/EC (13. BImSchV) 2000/76/EC (17. BImSchV) 27. BImSchV TA-Luft (Prevention of Air Pollution) EN 15267 EN 14181 MCERTS
Corrective FunctionsManual or automatic adjustment with test gases or adjustment cell
Test FunctionsSelf test & fault diagnosis
DescriptionDetermination of oxygen content using an electrochemical cell
Measurement PrinciplesElectrochemical cell
Measuring RangesO2: 0 … 10 Vol.-% / 0 … 25 Vol.-%
Certified Measuring RangesO2: 0 … 25 Vol.-%
Response Time (t90)20 s Typical at 60 l/h, depending on gas flow
Sensitivity Drift≤ 2 %: of measuring range full scale per week
Zero Point Drift≤ 2 %: of smallest measuring range per month
Process PressureAnalyser Inlet: –200 hPa … 300 hPa Relative
ConformitiesApproved for plants requiring approval – 2001/80/EC (13. BImSchV) 2000/76/EC (17. BImSchV) 27. BImSchV TA-Luft (Prevention of Air Pollution) EN 15267 EN 14181 MCERTS
Corrective FunctionsManual or automatic adjustment with test gases
Test FunctionsSelf test & fault diagnosis
DescriptionAccurate oxygen analyser which operates according to the paramagnetic measurement principle
Measurement PrinciplesParamagnetic dumbbell principle
Measuring RangesO2: 0 … 3 Vol.-% / 0 … 100 Vol.-% (Optional: smallest measuring range 0 … 1 vol%)
Certified Measuring RangesO2: 0 … 25 Vol.-%
Response Time (t90)≤ 4 s At a gas flow of 60 l/h
Sensitivity Drift≤ 1 %: of measuring range full scale per week
Zero Point Drift≤ 1 %: of smallest measuring range per week Measuring ranges smaller 5 vol%: ≤ 0.05 Vol.-%: per week
Process PressureAnalyser Inlet: –200 hPa … 300 hPa Relative
ConformitiesApproved for plants requiring approval – 2001/80/EC (13. BImSchV) 2000/76/EC (17. BImSchV) 27. BImSchV TA-Luft (Prevention of Air Pollution) EN 15267 EN 14181 MCERTS
Corrective FunctionsManual or automatic adjustment with test gases
Test FunctionsSelf test & fault diagnosis
RemarkSpecial versions with highly solvent-resistant or highly corrosion-resistant measuring cells available
DescriptionHeat conductivity analyser for the determination of concentrations in binary or quasi-binary gas mixtures
Measurement PrinciplesThermal conductivity measurement
Measuring RangesAr in N2: 0 … 10 Vol.-% / 0 … 100 Vol.-% Ar in O2: 0 … 10 Vol.-% / 0 … 100 Vol.-% CH4 in biogas: 0 … 60 Vol.-% / 0 … 100 Vol.-% CO2 in air: 0 … 10 Vol.-% / 0 … 100 Vol.-% H2 in Ar: 0 … 1 Vol.-% / 0 … 100 Vol.-% H2 in CH4: 0 … 1 Vol.-% / 0 … 100 Vol.-% H2 in CO2: 0 … 1 Vol.-% / 0 … 100 Vol.-% H2 in blast furnace gas: 0 … 1 Vol.-% / 0 … 100 Vol.-% H2 in N2: 0 … 1 Vol.-% / 0 … 100 Vol.-% He in N2: 0 … 2 Vol.-% / 0 … 100 Vol.-% NH3 in CO2: 0 … 15 Vol.-% / 0 … 100 Vol.-% NH3 in air: 0 … 15 Vol.-% / 0 … 100 Vol.-%
Response Time (t90)≤ 20 s At a gas flow of 60 l/h
Sensitivity Drift≤ 1 %: of measuring range full scale per week
Zero Point Drift≤ 1 %: of smallest measuring range per week Measuring ranges smaller than 2 x smallest measuring range: ≤ 2 %: of smallest measuring range per week
Corrective FunctionsManual or automated adjustment with test gases
Test FunctionsSelf test and fault diagnosis
DescriptionHighly selective NDIR analyser for continuous measurement of almost any gas component which absorbs in the infra-red spectral range
Measurement PrinciplesNDIR spectroscopy
Measuring RangesC2H2: 0 … 300 ppm / 0 … 100 Vol.-% C2H2F4: 0 … 100 ppm / 0 … 100 Vol.-% C2H4: 0 … 300 ppm / 0 … 30 Vol.-% N2O: 0 … 25 ppm / 0 … 100 Vol.-% NO: 0 … 75 ppm / 0 … 100 Vol.-% NH3: 0 … 300 ppm / 0 … 100 Vol.-% C3H6: 0 … 300 ppm / 0 … 100 Vol.-% C3H8: 0 … 100 ppm / 0 … 100 Vol.-% C4H6: 0 … 5,000 ppm / 0 … 20 Vol.-% CH4: 0 … 70 ppm / 0 … 100 Vol.-% CH3OH: 0 … 150 ppm / 0 … 10 Vol.-% CO: 0 … 20 ppm / 0 … 100 Vol.-% CO+CO2: 0 … 50 ppm / 0 … 100 Vol.-% CO2: 0 … 10 ppm / 0 … 100 Vol.-% COCl2: 0 … 200 ppm / 0 … 10 Vol.-% SF6: 0 … 50 ppm / 0 … 100 Vol.-% SO2: 0 … 26 ppm / 0 … 100 Vol.-% More than 60 measuring components available
Certified Measuring RangesCO: 0 … 75 mg/m³ / 0 … 750 mg/m³ / 0 … 3,000 mg/m³ CO2: 0 … 25 Vol.-% N2O: 0 … 50 mg/m³ / 0 … 500 mg/m³ NO: 0 … 100 mg/m³ / 0 … 1,000 mg/m³ / 0 … 2,000 mg/m³ SO2: 0 … 75 mg/m³ / 0 … 287 mg/m³ / 0 … 2,000 mg/m³ NOx: 0 … 100 mg/m³ / 0 … 1,000 mg/m³ / 0 … 2,000 mg/m³ CH4: 0 … 50 mg/m³ / 0 … 500 mg/m³
Response Time (t90)3 s Typical at 60 l/h, depending on cell length and gas flow
Sensitivity Drift≤ 1 %: of measuring range full scale per week
Zero Point Drift≤ 1 %: of measuring range full scale per week Measuring ranges smaller than 2 x smallest measuring range: ≤ 2 %: of measuring range full scale per week
ConformitiesApproved for plants requiring approval – 2001/80/EC (13. BImSchV) 2000/76/EC (17. BImSchV) 27. BImSchV TA-Luft (Prevention of Air Pollution) EN 15267 EN 14181 MCERTS
Corrective FunctionsManual or automatic adjustment with test gases or adjustment cell
Test FunctionsSelf test & fault diagnosis
Communication InterfaceModbus, Ethernet Type of fieldbus integration: TCP, RTU RS-485 Function: Connection to SOPAS ET software or OPC server
Number1
IndicationStatus LEDs: “Power,” “Failure,” and “Maintenance request” LC display
OperationVia LC display and membrane keyboard
DescriptionClosed module with top-hat rail adapter or module for integration into enclosures
Analog Outputs4 outputs: 0/2/4 … 20 mA, 500 Ω Electrically isolated
Analog Inputs2 inputs: 0/4 … 20 mA Not electrically isolated
Digital Outputs8 outputs: 34 V AC, 500 mA / 48 V DC, 500 mA
Digital Inputs8 inputs: 42 V All inlets with common reference potential
Sample Gas ConnectionsPVDF compression fitting: for hose 6 x 1 mm Swagelok 6 mm: stainless steel, for metal tube Swagelok 1/4″: stainless steel, for metal tube
OptionsMagnetic piston pump (0 … 60 l/h at 100 hPa low pressure) Humidity sensor Pressure sensor (500 … 1500 hPa) Flow sensor (0 … 100 l/h, ±20%)