SICK GMS800 FIDOR | Extractive Gas Analysers For Hydrocarbon Measurements

Gas analysis for continuous hydrocarbon measurements

BrandSICK
CategoryGas Detection
  • Quoted to your quantity
  • Documentation on request
  • International delivery

Product Overview

Sick GMS800 Fidor

Gas analysis for continuous hydrocarbon measurements

The GMS800 FIDOR is an extractive gas analyser manufactured by SICK, it is a member of the GMS800 analyser family. The GMS800 FIDOR extractive gas analyser is ideally suited to emission monitoring applications in waste incinerators or cement and power plants, for example.

Based on the proven flame ionization detection principle, the GMS800 FIDOR measures total hydrocarbon concentrations in gases at both trace and high concentration levels.

The SICK GMS800 FIDOR is available in three versions:

  • GMS810 FIDOR with integrated control unit (BCU),
  • GMS811 FIDOR with separate control unit (BCU),
  • GMS840 FIDOR with a space-saving wall housing which makes integration into existing systems such as SICK’s MCS100 E HW multi-component analyser very easy.

Features

  • Standard 19” enclosure for easy integration into all industry-typical systems
  • Space-saving wall housing (stand-alone)
  • Nearly maintenance free ejector pump delivers sample gas to the analyser
  • Integrated catalytic converter (option) provides very clean zero gas
  • Automatic regulation and compensation of process pressure fluctuations
  • Protective filter at sample gas inlet
  • High degree of linearity (≤ 2 %) for very low and high measuring ranges

Technical SPECIFICATION

Please note: The exact device specifications and performance data of the product may deviate from the information provided here, and depend on the application in which the product is being used and the relevant customer specifications.

FOR EXPLOSIVE ATMOSPHERES & Hazardous Areas

Key Product Categories: Control Panels | Plugs & Sockets | Isolators | Enclosures & Junction Boxes | Lighting | Control Stations | Motor Starters | Heat Trace Cables & Systems | Gas Detection & Detectors | Fire Detection & Detectors | Heat Detectors | Electrical Heating & Heaters

Also Process Instrumentation Products: Ashcroft Pressure Gauges | ASCO Valves | Katronic Flow Meters | KROHNE Flow Meters | VEGA Level Sensors | Rotronic Temperature & Humidity Sensors | SIKA Pressure Gauges

Technical Specifications

BrandSICK
CategoryGas Detection
Measured ValuesCorg
Performance Tested MeasurandsCorg
Gas Flow Rate≤ 120 l/h
Process Temperature≤ +230 °C
Process Pressure–120 hPa … 120 hPa Relative
Process Gas HumidityNon-condensing
Ambient Temperature+5 °C … +40 °C
Storage Temperature–20 °C … +70 °C
Ambient Pressure900 hPa … 1,100 hPa
Ambient Humidity≤ 95 % Non-condensing
ConformitiesApproved for plants requiring approval – 2001/80/EC (13. BImSchV) 2000/76/EC (17. BImSchV) 27. BImSchV TA-Luft (Prevention of Air Pollution) EN 15267 EN 14181 MCERTS
Electrical SafetyCE
Power SupplyPower consumption: Without external heating
AuxiliariesInstrument air: ≤ 1,000 l/h Instrument air: 4.5 ±0.5 bar Fuel gas: Typ. 30 ml/min Hydrogen: 5.0 or higher; 3 ±0.2 bar Combustion air: Typ. 250 ml/min Instrument air: 3 ±0.2 bar; measuring ranges below 300 ppm (500 mg/m³) require an internal or external catalytic converter Zero gas: ≤ 500 l/h Instrument air: 3 ±0.2 bar; measuring ranges below 300 ppm (500 mg/m³) require an internal or external catalytic converter Reference gas: ≤ 500 l/h Propane in synthetic air: 75% of measuring range full scale value Purge gas: > 1,200 l/h Air for case flushing, inlet
Corrective FunctionsAdjustment with test gases
Test FunctionsExtended device diagnosis via SOPAS ET software
Description19″ rack enclosure with 4 rack units, for integration in cabinets
Electrical SafetyCE
Enclosure RatingIP40
Dimensions (W x H x D)483 mm x 177 mm x 485 mm
Weight≤ 17 kg
Power SupplyVoltage: 90 … 240V Frequency: 47 … 63Hz Power consumption: ≤ 450 W
Sample Gas ConnectionsSample gas inlet: G 1/4″; G 1/8″ double, without antikink; G 1/8″ without antikink Exhaust gas outlet: 12 mm straight; 1/2″ straight; 10 mm 90° bent
Auxiliary Gas ConnectionsAuxiliary gas inlet: Varies depending on type
Description19″ rack enclosure with 4 rack units, for usage with separate control unit (BCU), for integration in cabinets
Electrical SafetyCE
Enclosure RatingIP40
Dimensions (W x H x D)483 mm x 177 mm x 352 mm
Weight≤ 17 kg
Power SupplyVoltage: 90 … 240V Frequency: 47 … 63Hz Power consumption: ≤ 450 W
Sample Gas ConnectionsSample gas inlet: G 1/4″; G 1/8″ double, without antikink; G 1/8″ without antikink Exhaust gas outlet: 12 mm straight; 1/2″ straight; 10 mm 90° bent
Auxiliary Gas ConnectionsAuxiliary gas inlet: Varies depending on type
DescriptionClosed sheet steel housing for wall mounting for use indoors
Electrical SafetyCE
Enclosure RatingIP54
Dimensions (W x H x D)522 mm x 475 mm x 478 mm
Weight20 kg
Power SupplyVoltage: 100 … 120 V / 220 … 240 V Frequency: 50 … 60Hz Power consumption: ≤ 300 W
Sample Gas ConnectionsSample gas inlet: Straight screw-in connection, 6 mm, G1/8″, stainless steel Exhaust gas outlet: G 1/4″
Auxiliary Gas ConnectionsDepending on type
DescriptionFlame ionization detector for measuring volatile organic components (VOC)
Measured ValuesCorg
Performance-Tested MeasurandsCorg
Measurement PrinciplesFlame ionisation detection
Gas Flow Rate≤ 120 l/h
Measuring RangesCorg: 0 … 15 mg/m³ / 0 … 10,000 mg/m³ A flame arrester must be provided by the customer when measuring gas concentrations above the lower explosion limit (LEL)
Certified Measuring RangesCorg: 0 … 15 mg/m³ / 0 … 50 mg/m³ / 0 … 150 mg/m³ / 0 … 500 mg/m³
Response Time (t90)≤ 2.5 s Without sample gas line
Sensitivity Drift< 3 %: within the maintenance interval, relative to measuring range full scale
Zero Point Drift< 3 %: within the maintenance interval, relative to measuring range full scale
Detection LimitCorg: 0.05 mg/m³
Electrical SafetyCE
DescriptionThe control unit serves as the human machine interface and is responsible for data processing and output as well as control and monitoring functions.
IndicationStatus LEDs: “Power,” “Failure,” and “Maintenance request”, LC Display
OperationVia LC display and membrane keyboard
Dimensions (W x H x D)For separate BCU control unit: 375 mm x 275 mm x 66 mm
DescriptionClosed module with top-hat rail adapter or module for integration into enclosures
Analog Outputs4 outputs: 0/2/4 … 20 mA, 500 Ω Electrically isolated
Analog Inputs2 inputs: 0/2/4 … 20 mA, 500 Ω Not electrically isolated
Digital Inputs8 inputs: + 42 V All inlets with common reference potential
Communication InterfaceModbus, Ethernet Type of fieldbus integration: TCP, RTU RS-485 Function: Connection to SOPAS ET software or OPC server