SICK ZIRKOR302 | In-Situ Gas Analysers For Oxygen Measurement

The Other Kind Of Oxygen Measurement

BrandSICK
CategoryGas Detection
  • Quoted to your quantity
  • Documentation on request
  • International delivery

Product Overview

Sick ZIRKOR302

The Other Kind Of Oxygen Measurement

The ZIRKOR302 in-situ gas analyser from SICK can be relied upon to measure oxygen quickly even at increased temperatures. The flow sensor measurement principle and fully automated calibration using ambient air means it does not require expensive test gases.

The Zirconium Dioxide oxygen analyser is not an ignition source in the gas detection process thanks to its safety-related design and construction which are compliant with national legal requirements of TuV, GOST and KAITEC, regarding the measurement of oxygen levels in flue gas.

Typical Applications for SICK ZIRKOR302

  • Reference value formation during emission monitoring
  • Monitoring of oxygen surpluses
  • Monitoring of inert gas atmospheres

Features

  • Innovative flow sensor measurement principle
  • Fixed physical zero point and linear measurement signal
  • All parts in contact with gas are heated
  • Version for high temperatures available
  • Short response time
  • Operation of up to three analysers via one evaluation unit

SICK ZIRKOR302 analyser unit

Please note: The exact device specifications and performance data of the product may deviate from the information provided here, and depend on the application in which the product is being used and the relevant customer specifications.

FOR EXPLOSIVE ATMOSPHERES & Hazardous Areas

Key Product Categories: Control Panels | Plugs & Sockets | Isolators | Enclosures & Junction Boxes | Lighting | Control Stations | Motor Starters | Heat Trace Cables & Systems | Gas Detection & Detectors | Fire Detection & Detectors | Heat Detectors | Electrical Heating & Heaters

Also Process Instrumentation Products: Ashcroft Pressure Gauges | ASCO Valves | Katronic Flow Meters | KROHNE Flow Meters | VEGA Level Sensors | Rotronic Temperature & Humidity Sensors | SIKA Pressure Gauges

Technical Specifications

BrandSICK
CategoryGas Detection
ZIRKOR302 E Analyser UnitZIRKOR302 P Analyser Unit
DescriptionAnalyser with ejector operating with compressed airAnalyser with integrated sample gas pump
Measured ValuesO2
Performance-Tested MeasurandsO2
Measurement PrinciplesZirconium dioxide current sensor
Gas Flow Rate0.5 l/h
Measuring Ranges0 … 10 Vol.-% / 0 … 25 Vol.-%
Certified Measuring Ranges0 … 21 Vol.-%
Response Time (t90)≤ 20 s (With standard gas sampling device, length = 1 m)
Zero Point Drift≤ 0.2 Vol.-%: within the maintenance interval
Reference Point Drift≤ 0.2 Vol.-%: within the maintenance interval
Process TemperatureStainless steel probe: 0 °C … +700 °C Inconel probe: 0 °C … +950 °C Ceramic probe: 0 °C … +1,400 °C
Process Pressure700 hPa … 1,100 hPa
Process Gas HumidityNon-condensing
Ambient Temperature–20 °C … +55 °C
Storage Temperature–40 °C … +85 °C
ConformitiesApproved for plants requiring approval: EN 14181 2000/76/EC (17. BImSchV) 2001/80/EC (13. BImSchV) 27. BImSchV
Electrical SafetyCE
Enclosure RatingIP65 / NEMA 4x
Analog Outputs1 output: 0/4 … 20 mA, + 800 Ω 0 … 10 V Potential-free; extendible by an additional I/O module
Digital Outputs4 relay contacts: + 48 V AC, 1 A, 30 W / 48 V DC, 1 A, 60 W Option
Digital Inputs4 inputs: + 24 V Option
IndicationLC display
InputFunctional keys Arrow keys
OperationMenu-driven operation via LC display and membrane keyboard
Dimensions (W x H x D)Dimensions may vary. See data sheet
Weight27 kg (With standard gas sampling device, length = 1 m) With heating for gas sampling device, additional: 4 kg … 6 kg
Material In Contact With MediaStainless steel 1.4571
Power SupplyVoltage: 115 V//230 V Frequency: 48 … 62 Hz Power consumption: ≤ 250 W
AuxiliariesCompressed air: 4 … 6 bar; particle size max. 1 µm; oil content max. 0.1 mg/m³; pressure dew point max. –30 °CX
Corrective FunctionsAutomatic testing and adjustment with ambient air
Integrated ComponentsSample gas pump
DescriptionThe control unit serves as the human machine interface and is responsible for data processing and output as well as control and monitoring functions.
Enclosure RatingIP65/NEMA 4x
Analog Outputs3 outputs: 0/4 … 20 mA, + 500 Ω Electrically isolated; one measured value output per connected analyser
Digital Outputs2 relay contacts: + 150 V AC, 1 A, 60 W / 125 V DC, 1 A, 30 W
Digital Inputs3 inputs: + 24 V (Pre-set for failure, maintenance and functional control)
Communication InterfaceSerial CAN bus Type of fieldbus integration: RS-232 Function: Connection to SOPAS ET software Internal system bus
Number1
IndicationLC display Status LEDs: “Power,” “Failure,” and “Maintenance request”
InputArrow keys & Functional keys
OperationMenu-driven operation via LC-display and membrane keyboard
ModelSteel sheet enclosure
Dimensions (W x H x D)200 mm x 346 mm x 97.5 mm
Weight4 kg
Power SupplyVoltage: 115 V/230 V Frequency: 50 Hz/60 Hz Power consumption: ≤ 50 W Recommended pre-fuse: 10A
DescriptionThe control unit serves as the human machine interface and is responsible for data processing and output as well as control and monitoring functions.
Enclosure RatingIP67/NEMA 4x
Analog Outputs3 outputs: 0/4 … 20 mA, + 500 Ω Electrically isolated; one measured value output per connected analyser
Digital Outputs3 relay contacts: + 48 V AC, 1 A, 60 W / 48 V DC, 1 A, 30 W Pre-set for failure, maintenance and functional control
Digital Inputs3 inputs: + 24 V
Communication InterfaceSerial CAN bus Type of fieldbus integration: RS-232 Function: Connection to SOPAS ET software Internal system bus
Number1
IndicationLC display Status LEDs: “Power,” “Failure,” and “Maintenance request”
InputArrow keys & Functional keys
OperationMenu-driven operation via LC-display and membrane keyboard
ModelCast metal enclosure
Dimensions (W x H x D)200 mm x 346 mm x 97.5 mm
Weight4 kg
Power SupplyVoltage: 115 V/230 V Frequency: 50 Hz/60 Hz Power consumption: ≤ 50 W Recommended pre-fuse: 10A