| Rated voltage | 300 V |
|---|---|
| Conductor | Annealed stranded bare copper per ASTM B‐174 and UL62 |
| Insulation | EPDM 90ºC Compound Class3 , Table8 UL62 |
| Outer sheath | Chlorinated Polyethlene (CPE) compound class 1.4 ,UL62 , table15 |
| Assembly | Insulated cores cabled together with integral fillers |
| Color | Black (All other colors available) |
| Temperature range | -40°C (-40°F) to 90°C (194°F) |
| Minimum bending radius | 6xD (fixed) |
| Flexible cords and cables | CAN/CSA-C22.2 No.49-18 |
| Wire and cable test methods | UL2556 -15 , CSA C22.2 |
| Flexible cords and cables | CAN/CSA‐C22.2 No.49 |
| Flame test | FT2; RoHS |
| Part Number | Number of Cores and Size | No of wire x Diameter of Wire | Nominal Insulation Thickness | Cable Diameter Approx. (Tolerance ±5%) | Cable Weight Approx. | Cable Weight Approx. | ||
|---|---|---|---|---|---|---|---|---|
| No. x..AWG | No. x ..AWG | inches | mm | mm | inches | kg/km | Ibs/MF | |
| UNT18-02SJOOW | 2 x 18AWG | 16 x 30 | 0,03 | 0,76 | 7,4 | 0,291 | 59 | 40 |
| UNT16-02SJOOW | 2 x 16AWG | 26 x 30 | 0,03 | 0,76 | 8 | 0,315 | 73 | 49 |
| UNT16-03SJOOW | 3 x 16AWG | 26 x 30 | 0,03 | 0,76 | 8,5 | 0,335 | 96 | 65 |
| UNT16-04SJOOW | 4 x 16AWG | 26 x 30 | 0,03 | 0,76 | 9,4 | 0,37 | 120 | 80 |
| UNT14-02SJOOW | 2 x 14AWG | 41 x 30 | 0,03 | 0,76 | 8,8 | 0,346 | 96 | 65 |
| UNT14-03SJOOW | 3 x 14AWG | 41 x 30 | 0,03 | 0,76 | 9,4 | 0,37 | 130 | 37 |
| UNT14-04SJOOW | 4 x 14AWG | 41 x 30 | 0,03 | 0,76 | 10,7 | 0,421 | 173 | 116 |
| UNT12-02SJOOW | 2 x 12AWG | 65 x 30 | 0,03 | 0,76 | 10,3 | 0,406 | 140 | 94 |
| UNT12-03SJOOW | 3 x 12AWG | 65 x 30 | 0,03 | 0,76 | 11 | 0,433 | 185 | 124 |
| UNT12-04SJOOW | 4 x 12AWG | 65 x 30 | 0,03 | 0,76 | 12,2 | 0,48 | 240 | 161 |
| UNT10-02SJOOW | 2 x 10AWG | 104 x 30 | 0,045 | 1,14 | 14 | 0,551 | 246 | 165 |
| UNT10-03SJOOW | 3 x 10AWG | 104 x 30 | 0,045 | 1,14 | 15 | 0,591 | 320 | 215 |
| UNT10-04SJOOW | 4 x 10AWG | 104 x 30 | 0,045 | 1,14 | 17 | 0,67 | 425 | 286 |
Tell us your quantity and requirements — we reply within one business day.
Industrial CablesFixed installation for power, control and lighting in both and safe areas applications.
Industrial Cables3GKW MM Flex Industrial Cable for industrial applications. Construction: Tinned fine copper strands (class 5 acc. to IEC 60228); Cross-linked elastomeric special compound; Cross-linked elastomeric special compound.
Industrial Cables3GKW M Industrial Cable for industrial applications. Construction: Electrolytic tinned, class 5 stranded copper wires (Iec 60228); Halogen‐free. heat resistant. cross‐linked elastomeric special compound (Requirements based on type El 109…
Share your specifications and quantities. Our team will review your request and come back with sourcing options and a quotation.