Trace Heating Cables for Hot Water Supply & Maintenance | Nelson LT-C1 Cable

Nelson Heat Trace LT Type self-regulating trace heating cables provide hot water temperature maintenance to pipework systems, maintaining water up to 60ºC and reducing or eliminating the delay in obtaining hot water…

CategoryHeat Tracing Cables & Systems
  • Quoted to your quantity
  • Documentation on request
  • International delivery

Product Overview

Trace Heating

Nelson Heat Trace LT Type self-regulating trace heating cables provide hot water temperature maintenance to pipework systems, maintaining water up to 60ºC and reducing or eliminating the delay in obtaining hot water at each fixture.

This cable system eliminates the need for return piping, pumps, check valves and pressure balancing valves found in recirculating systems, as well as reducing maintenance requirements by eliminating any devices with moving parts which would be connected to the re-circulation system.

The Nelson Heat Trace LT heater cable can be used in all hot water supply systems, especially in hotels, hospitals, prisons and other installations where the point of use may be far from the main hot water supply.

Nelson LT features

  • Ensure a reliable hot water supply at a consistent temperature of 105°F, 115°F, 125°F or 140°F, in accordance with ASHRAE guidelines for domestic service water heating
  • Available for 208 Vac and 120 Vac supply voltages
  • Both UL Listed and CSA Approved for use in non-hazardous locations
  • Heating Cable LT-A: 208 Vac, 41°C/105°F
  • Heating Cable LT-B: 208 Vac, 46°C/115°F
  • Heating Cable LT-C: 208 Vac, 52°C/125°F
  • Heating Cable LT-D: 208 Vac, 60°C/140°F
  • Heating CableLT-C1: 120 Vac, 52°C/125°F

certifications & Compliances

The heating cables are UL Listed for domestic hot water temperature maintenance and meet all requirements of IEEE Standard 515.1, Recommended Practice for the Testing, Design, Installation, and Maintenance of Electrical Resistance Heat Tracing for Commercial Applications.

  • UL Listed: E53501
  • Other Standard: IEEE 515.1-2012

Technical Specifications

CategoryHeat Tracing Cables & Systems
Nelson Heat Trace Cable Part NumberSupply VoltageMaximum Segment LengthNominal Maintenance TemperatureAmbient Temperature RangeColour Code
LT-C1120100.6 m / 330 ft52ºC / 125ºF21-26ºC / 70-78ºFPurple