Wolf Airlamp Turbolite – Zone 1 & Zone 2 Hazardous Area

Wolf A-TL44 | Wolf A-TL45

CategoryATEX Portable & Temporary Lighting
  • Quoted to your quantity
  • Documentation on request
  • International delivery

Product Overview

Hazardous Area Airlamps

Wolf A-TL44 | Wolf A-TL45

Airlamps for Zone 1, Zone 2 Hazardous Area Lighting

Wolf Turbolite airlamps are able to offe suitable lighting alternative solution to low voltage lighting in wet conditions. In particular for applications in the oil and petrochemical industries such as tank cleaning and pipeline inspections where flammable gases and vapours can accumulate in confined spaces.

The Turbolite airlamps all have bay light fitting comprising a ball glass and protective polycarbonate dome to provide all-round general purpose illumination. Hooks are also present so the airlamps can be suspended in the work area or attached to a folding tripod. They must all use an anti-static hose to prevent the generation of unsafe levels of static electricity.

Airlamps For Hazardous Areas

Wolf Turbolite airlamp provides reliable and versatile hazardous area lighting – the airlamps utilise tungsten halogen technology as a light source and are used for safe lighting in hazardous area Zones 1 and Zones 2 (potentially explosive gas atmospheres) (IIA, IIB & IIC Groups) with T4 temperature classification.

An overview of the Wolf Turbolite airlamps range to provide portable lighting in explosive atmospheres:

  • Wolf A-TL44 Turbolite Airlamp Zone 1
  • Wolf A-TL45 Turbolite Airlamp Zone 1
  • Certification: Ex s II T4
  • Hazardous Area Zone 1 & 2 Gas Groups IIA, IIB & IIC
  • Temperature Classification (Gas) T4 | See more information about T Class Ratings
  • More Technical Information Hazardous Area Zones

Wolf Turbolite airlamp

  • 250 Watt Halogen Ultimate Output
  • Electronic Setting Device
  • Generator Overspeed Protector
  • Advanced Internal Topology Rotor Design
  • Spark Free Brass Casings
  • Full Accessory Range Available

Zones 1 & 2 Hazardous Areas

  • Zone 1 & Zone 2 Gas
  • See below table for Certification details including T-Rating, Gas Groups and Zone locations

The Wolf Turbolite range are airlamps manufactured by Wolf Safety Lamp to provide lighting in Zone 1 & Zone 2 hazardous areas – the tungsten halogen airlamps are for use in potentially explosive atmospheres.

Light Output & Product Dimensions

A-TL44 – Ball Glass
Peak luminous intensity at 2.5m 70lux

A-TL45 – Polished Reflector
Spot Beam (approx 10°)
Peak luminous intensity at 5m 2000lux

A-TL45 – Matt Reflector
Flood Beam (approx 25°)
Peak luminous intensity at 5m 950lux

Technical Specifications

CategoryATEX Portable & Temporary Lighting
Wolf Turbolite Part ReferenceWolf A-TL44Wolf A-TL45
Airlamp DescriptionSafety Bay Light, Compressed Air PoweredSafety Flood LightCompressed Air Powered
Hazardous Area CodeEx s II T4
Apparatus StandardsSFA 3009:1972
Type of Protection“s” special protection
Area of Hazardous Classification (Gas)Zones 1 and 2, Gas Groups IIA, IIB, IIC
Temperature ClassificationT4
Ambient Temperature-20ºC to +40ºC
ATEX CertificateBASEEFA Ex 78209X*
EnclosureNickel Plated Brass and Gun Metal
LensBall Glass/Polycarbonate DomeToughened Glass (15mm)
Beam TypeAll-around 360° IlluminationFlood (Matt Reflector) (as standard) or Spot (Polished Reflector) (to order)
Light SourcePart ReferenceA-129 (as std) or A-159 (as alt)A-129 (as std) or A-159 (as alt)
TypeTungsten Halogen Filled Filament Bulb
Volts24v
Watts250w
Output6000 lm – 9000 lm6000 lm – 9000 lm
Life2000 hrs – 200 hrs2000 hrs – 200 hrs
Power SourceTypeCompressed Air Driven Turbo-alternator
Air Pressure4.0-8.0 bar
Consumption0.75m3/min
Ingress ProtectionOnce pressurised may be used underwater
Weight7.9kg12.2kg
*Special certification conditionsA clean dry air supply must be used. Supply hose must be anti-static.

Request Information About This Product

Tell us your quantity and requirements — we reply within one business day.

Related Products

Have a product requirement?

Share your specifications and quantities. Our team will review your request and come back with sourcing options and a quotation.