Zone 1 Fluorescent Hazardous Area Lighting ATEX Ex db – Petrel 7 Series

Zone 1 Fluorescent Hazardous Area Lighting

CategoryATEX Lighting (Zone 1 & Zone 2)
  • Quoted to your quantity
  • Documentation on request
  • International delivery

Product Overview

Zone 1 Fluorescent Hazardous Area Lighting

ATEX Classification – Ex d II 2 G IIB or IIC T* Protection IP 66

Petrel 7 Series are high output fluorescent lighting suitable for Zone 1 hazardous area lighting applications with a wide range of lamps to be fitted from 8W to 70W. Available in both standard and emergency formats the Zone 1 ATEX light fittings have a range of sizes 1-6ft with a light output up to 12,400 lumens (subject to lamp choice).

Zone 1 fluorescent light fittings are manufactured from impact resistant polycarbonate and high specification marine grade aluminium – the hazardous area Zone 1 fluorescent light fitting is supplied anodised and painted.

Fluorescent emergency models are fitted with integral batteries (minimum 3 hour duration) and charging units for ease of fitting and maintenance – Zone 2 fluorescent version also available.

Hazardous Area & atex Approved

  • Certification and Hazardous Area Approval Certification Code: II 2 G Ex db IIB/IIC Gb T*Ex tb IIIC T* Db
  • Certification Number: CML14ATEX 1028X IECEx CML140012X
  • Certification Standard: EN 60079, IEC 600791
  • Protection: IP 66

Benefits & Options

  • Easily compatible – 24V to 254V fluorescent light fittings available
  • 50/60Hz compatible
  • Can be used in Zone 1 high ambient temperatures (up to 55°C)
  • Through wiring (loop in, loop out) installation option. Use /TW suffix on reference code
  • Single lamp fluorescent versions: Petrel 7108/S1/240/50 (1x8W), 7118/S2/240/50 (1x18W), 7136/S4/240/50 (1x36W), 7158/S5/240/50 (1x 58W), 7170/S6/240/50 (1x70W)
  • Twin lamp fluorescent versions: Petrel 7208/S1/240/50 (2x8W), 7218/S2/240/50 (2x18W), 7236/S4/240/50 (2x36W), 7258/S5/240/50 (2x58W), 7270/S6/240/50 (2x70W)
  • Sizes: S1 1x8W, 2x8W (448mm, 1ft). S2 1x18W, 2x18W (752mm, 2ft). S4 1x36W, 2x36W (1362mm, 4ft). S5 1x58W, 2x58W (1662mm, 5ft). S6 1x70W, 2x70W (1926mm, 6ft)
  • 230v 50/60Hz Check for alternative voltages
  • -20°C to +55°C standard supply subject to lamp and ambient temperature combinations (ask for details)
  • 8w (T5), 18w, 36w, 58w, 70w (T8) (Lamps not provided)

where S = single lamp fitting and T = twin light fitting.

hazardous area zone 1 Single & Twin Light Fittings

Petrel Zone 1 fluorescent lighting fittings are available as single or twin lamps in 8 watts, 18 watts, 36 watts and 58 watts, 70 watts – contact our team to discuss your hazardous area lighting requirements, we can provide lighting design layouts from the very simple to the extremely complex.

Zone 1

Ordering Information

Note: Lumen output dependent on lamp specification

To order Emergency variant add “/EM” to part number.
8w version available in non maintained, add “NM”

Technical Specifications

CategoryATEX Lighting (Zone 1 & Zone 2)
Zone 1 Fluorescent Luminaire Sizes – Petrel 7 SeriesATEX Certified Lighting
Standard Fluorescent Range
1 (Single) or 2 (Twin) x 8 WattsZone 1 Ex d
1 (Single) or 2 (Twin) x 18 WattsZone 1 Ex d
1 (Single) or 2 (Twin) x 36 WattsZone 1 Ex d
1 (Single) or 2 (Twin) x 58 WattsZone 1 Ex d
1 (Single) or 2 (Twin) x 70 WattsZone 1 Ex d
Emergency Fluorescent Range
1 (Single) or 2 (Twin) x 8 WattsZone 1 Ex d
1 (Single) or 2 (Twin) x 18 WattsZone 1 Ex d
1 (Single) or 2 (Twin) x 36 WattsZone 1 Ex d
1 (Single) or 2 (Twin) x 58 WattsZone 1 Ex d
Standard Fluorescent RangeEmergency Fluorescent Range
Supply Voltage230V 50/60Hz standard. Check for alternative voltages230V 50/60Hz standard. Check for alternative voltages, Suitable for central battery operation
Operating Temperature-20ºC to +55ºC standard supply subject to lamp ambient temperature requirements
Control GearElectronic ballastElectronic ballast. One lamp lit in emergency mode.
Lamp Options8W (T5), 18W, 36W, 58W, 70W (T8) (Lamps not provided)8W (T5), 18W, 36W, 58W (Lamps not provided)
Cable Entries4 x M20 – 2 each end (3 plugged) as standard other threads available
Terminals3 wire and earth. Cable size 4mm² max. Through wiring option available on 18W to 70W sizes3 wire and earth. Cable size 4mm² max. Through wiring option available on 18W to 58W sizes
Mounting Facility2 x M8 tapped holes vertical and horizontal at both ends Size 1 335mm, Size 2 632mm, Size 4 1,242mm, Size 5 1,542mm, Size 6 1,806mm
AccessTerminals accessed via threaded end cover as is the gear tray which slides out
MaterialCorrosion resistant marine grade anodised Aluminium body and high impact polycarbonate tube
WeightSize 1 – 3.0kgs Size 2 – 5.0kgs Size 4 – 4.7kgs Size 5 – 8.0kgs Size 6 – 9.0kgs
SizeA/mmB/mm
1335448
2632752
41,2421,362
51,5421,662
61,8061,962
Part NumberOrder RefFluorescent Light DescriptionLight SourcePower ConsumptionSize (mm)
1H607011997108/S1/HF8w Ex d Zone 1 LuminaireSingle Tube Fluorescent1 x 8 watt448
1H607021997118/S2/HF18w Ex d Zone 1 LuminaireSingle Tube Fluorescent1 x 18 watt752
1H607041997136/S4/HF36w Ex d Zone 1 LuminaireSingle Tube Fluorescent1 x 36 watt1,362
1H607051997158/S5/HF58w Ex d Zone 1 LuminaireSingle Tube Fluorescent1 x 58 watt1,662
1H607061997170/S6/HF70w Ex d Zone 1 LuminaireSingle Tube Fluorescent1 x 70 watt1,926
1H607012997208/S1/HF2x8w Ex d Zone 1 LuminaireTwin Tube Fluorescent2 x 8 watt448
1H607022997218/S2/HF2x8w Ex d Zone 1 LuminaireTwin Tube Fluorescent2 x 18 watt752
1H607042997236/S4/HF2x36w Ex d Zone 1 LuminaireTwin Tube Fluorescent2 x 36 watt1,362
1H607052997258/S5/HF2x58w Ex d Zone 1 LuminaireTwin Tube Fluorescent2 x 58 watt1,662
1H607062997270/S6/HF2x70w Ex d Zone 1 LuminaireTwin Tube Fluorescent2 x 70 watt1,926

Request Information About This Product

Tell us your quantity and requirements — we reply within one business day.

Related Products

Have a product requirement?

Share your specifications and quantities. Our team will review your request and come back with sourcing options and a quotation.