FM2XCH-FFR Marine Cable

Used as control and signal cables in various electromechanical and electronic equipments of marine vehichles, in most areas & open deck in ships. Due to its’ overall screen the electromagnetic…

Rated voltage150 / 250 V
ConductorElectrolytic, stranded, annealed copper wire IEC 60228 Class 2 (Class 5 and/or tinned on request)
InsulationCross linked polyethylene compound (XLPE). Each pair formed by white cores with black numbers
Outer sheathHalogen-free, flame retardant, UV resistant, polyolefin based compound (SHF 1)
  • Quoted to your quantity
  • Documentation on request
  • International delivery

Product Overview

Used as control and signal cables in various electromechanical and electronic equipments of marine vehichles, in most areas & open deck in ships. Due to its’ overall screen the electromagnetic interference is minimized.

* Minimum recommended installation temperature -15°C

For core identification, diameter tolerances and current ratings etc. see technical information section

Technical Specifications

Rated voltage150 / 250 V
ConductorElectrolytic, stranded, annealed copper wire IEC 60228 Class 2 (Class 5 and/or tinned on request)
InsulationCross linked polyethylene compound (XLPE). Each pair formed by white cores with black numbers
Outer sheathHalogen-free, flame retardant, UV resistant, polyolefin based compound (SHF 1)
Working temperature-40°C / + 90°C
Fire barrierMica Tape
Inner coveringSeparating foil
ScreenElectrolytic copper braided screen (Min. 90% coverage) (Tinned copper wire braid on request)
ColorOrange or Green
ConstructionIEC 60092 / 376
Tests and materialIEC 60092 / 350-360
Flame retardantIEC 60332 / 1, IEC 60332 / 3-22 Cat A
Fire resistanceIEC 60331 / 21, IEC 60331 / 1-2
Halogen contentIEC 60754 / 1-2
Smoke emissionIEC 61034 / 1-2 (DIN EN 50268 / 1-2)
Ozon resistanceIEC 60811 / 403
Min. bending radius (fixed)6xD
Test voltage1,5 kV
UV and sunlight resistanceEN 50289-4-17 A&B, ISO 4892-2&3
Nominal Cross-Section (mm²)Cable Outer Diameter (mm)Approximate Cable Weight (kg/km)Minimum bending radius (fixed) (mm)Maximum Conductive Resistance at 20°C (ohms/km)Current carrying capacity at 45°C (A)
1x2x0,57.2704440.411
1x4x0,58.1954940.49
5x2x0,512.92027840.46
7x2x0,514.52808740.45
8x2x0,515.63109440.45
10x2x0,518.339011040.45
12x2x0,518.842411340.45
14x2x0,519.948012040.44
16x2x0,52153012640.44
18x2x0,522.258513440.44
19x2x0,522.260513440.44
20x2x0,523.263014040.44
24x2x0,523.670514240.44
37x2x0,529.6102518040.43
1x2x0,758.190492613
1x4x0,759.4125572611
2x2x0,7511.9155722611
4x2x0,7514.326086268
5x2x0,7515.530093267
6x2x0,7516.9346102267
7x2x0,7516.9368102267
8x2x0,7518.3413110266
10x2x0,7521.4510129266
12x2x0,7522.3580134266
14x2x0,7523.4640141265
16x2x0,7524.8716149265
18x2x0,7526.1786157265
19x2x0,7526.1810157265
20x2x0,7527.6864166265
24x2x0,7530.71020185265
37x2x0,7535.81510215264
1x2x18.5965119.216
1x4x19.71365919.213
2x2x112.21707419.213
4x2x114.72808919.29
5x2x1163259619.29
6x2x117.438010519.28
7x2x117.440510519.28
8x2x118.845211319.28
10x2x122.357213419.27
12x2x12363813819.27
14x2x124.171014519.26
16x2x125.679515419.26
18x2x126.987016219.26
19x2x126.990016219.26
20x2x128.596017119.26
24x2x128.9108017419.26
37x2x136.9168222219.25
1x2x1,59.51205712.820
1x4x1,510.91746612.817
2x2x1,514.42468712.817
4x2x1,516.836410112.812
5x2x1,518.443011112.811
6x2x1,520.149012112.810
7x2x1,520.154012112.810
8x2x1,521.760013112.89
10x2x1,525.776515512.89
12x2x1,526.585015912.89
14x2x1,528.196516912.88
16x2x1,529.6107017812.88
18x2x1,531.3118518812.87
19x2x1,531.3123018812.87
20x2x1,533.2131220012.87
24x2x1,533.7147820312.87
37x2x1,543229025812.86

Features

  • Halogen-free
  • Low smoke
  • Flame retardant
  • Non-corrosive

Certifications / Standards

  • American Bureau of Shipping (ABS)
  • Bureau Veritas (BV)
  • ClassNK
  • DNV
  • Lloyd's Register (LR)
  • RINA
  • Russian Maritime Register of Shipping (RMRS)
  • Türk Loydu

Request Information About This Product

Tell us your quantity and requirements — we reply within one business day.

Related Products

MGCH Marine CableMarine Cables
Cables

MGCH Marine Cable

Used as fixed installation cables in various electromechanical and electronic equipments of marine vehicles. Due to its’ overall screen, environmental electromagnetic interference is minimized.

0,6 / 1 kV · -40°C / + 90°C

Have a product requirement?

Share your specifications and quantities. Our team will review your request and come back with sourcing options and a quotation.