M2XH-FFR (FI) Marine Cable

Used on marine vehicles as fixed installation cables of various electromechanical and electronic equipments, where sustainable connection during fire is required.

Rated voltage0,6 / 1 kV
ConductorElectrolytic, stranded, annealed copper wire IEC 60228 Class 5 (Class 2 and / or tinned on request)
InsulationCross linked polyethylene compound (XLPE)
Outer sheathHalogen-free, flame retardant, UV resistant, thermoplastic polyolefin based compound (SHF 1)
  • Quoted to your quantity
  • Documentation on request
  • International delivery

Product Overview

Used on marine vehicles as fixed installation cables of various electromechanical and electronic equipments, where sustainable connection during fire is required.

*Minimum recommended installation temperature -15°C

For core identification, diameter tolerances and current ratings etc. see technical information section

Technical Specifications

Rated voltage0,6 / 1 kV
ConductorElectrolytic, stranded, annealed copper wire IEC 60228 Class 5 (Class 2 and / or tinned on request)
InsulationCross linked polyethylene compound (XLPE)
Outer sheathHalogen-free, flame retardant, UV resistant, thermoplastic polyolefin based compound (SHF 1)
Working temperature-40°C / + 90°C
Fire barrierMica tape
Inner coveringHalogen-free compound
ColorOrange or Green
FIWith extruded bedding compound
ConstructionIEC 60092 / 353
Tests and materialIEC 60092 / 350-360
Flame retardantIEC 60332 / 1-2, IEC 60332 / 3-22 Cat A
Fire resistantIEC 60331 / 21, IEC 60331 / 1-2
Halogen contentIEC 60754 / 1-2
Smoke emissionIEC 61034 / 1-2 (DIN EN 50268 / 1-2)
Ozon resistanceIEC 60811 / 403
Min. bending radius (fixed)For cables D ≤ 25 mm 4xD, For cables D > 25 mm 6xD
Test voltage3,5 kV
UV and sunlight resistanceEN 50289-4-17 A&B, ISO 4892-2&3
MGM 110 DOUBLE LA VER ARMOURED SIGNAL CABLE
Cross section2×1,54×1,57×1,510×1,512×1,514×1,519×1,537×1,561×1,591×1,5
Conductors
Conductor diameterNam. mm1.50
lnsu/ation thicknessmm0.5
Core diametermm2,36 (min) – 2,64 (max)
Cable details
Radia/ thickness of inner sheathmm1.01.01.01.01.01.01.01.21.21.4
Size of armourmm1/0,91/0,91/0,91/1,251/1,251/1,251/1,251/1,61/1,61/2,0
Radial thickness of outer sheathmm1.51.61.61.71.71.71.81.92.12.3
Min. overa/1 diametermm15.917.017.522.823.223.825.332.537.745.1
Max. overa/1 diametermm17.318.619.124.424.825.827.334.940.147.9
Min. bending radiusmm156168172220224233246315361432
Appx. cab/e weightkg/km5706808201,2801,3501,4501,6502,8503,0005,600
Copper weightkg/km30601051501802102805408801,315
MGM 110 DOUBLE LA VER ARMOURED TELEPHONE CABLE
Cross section1x2x1,52x2x1,54x2x1,57x2x1,510x2x1,512x2x1,519x2x1,527x2x1,530x2x1,537x2x1,548x2x1,561x2x1,5
Conductors
Number and cross sectionmm21x2x1,52x2x1,54x2x1,57x2x1,510x2x1,512x2x1,519x2x1,527x2x1,530x2x1,537x2x1,548x2x1,561x2x1,5
Strandingmm7/0,5
Conductor diameterNam. mm1.50
lnsu/ation thicknessmm0.5
Core diametermm2,36 (min) – 2,64 (max)
Cable details
Radia/ thickness of inner sheathmm1.01.01.01.01.21.21.21.41.41.41.41.6
Size of armourmm1/0,91/0,91/1,251/1,251/1,61/1,61/1,61/2,01/2,01/2,01/2,01/2,5
Radial thickness of outer sheathmm1.41.51.61.71.91.92.02.22.22.32.42.6
Min. overa/1 diametermm15.917.022.725.332.032.436.243.644.747.352.558.8
Max. overa/1 diametermm17.318.624.427.334.034.838.646.247.350.155.362.0
Min. bending radiusmm156168220246306314348416426451498558
Appx. cab/e weightkg/km5706801,2501,5802,3502,5503,2804,6804,9505,6206,5908,800
Copper weightkg/km30601202102903505507808701,0701,3901,760

Features

  • Halogen-free
  • Low smoke
  • Flame retardant
  • Non-corrosive

Certifications / Standards

  • Bureau Veritas (BV)
  • DNV
  • Lloyd's Register (LR)
  • RINA
  • Russian Maritime Register of Shipping (RMRS)
  • Türk Loydu

Request Information About This Product

Tell us your quantity and requirements — we reply within one business day.

Related Products

MGCH Marine CableMarine Cables
Cables

MGCH Marine Cable

Used as fixed installation cables in various electromechanical and electronic equipments of marine vehicles. Due to its’ overall screen, environmental electromagnetic interference is minimized.

0,6 / 1 kV · -40°C / + 90°C

Have a product requirement?

Share your specifications and quantities. Our team will review your request and come back with sourcing options and a quotation.