ATEX Doors | Dynaco S-559 Zone 1 & 21 High Speed Door – All WeatherATEX Doors | Dynaco S-535 High Speed Door – Interior
High Speed Roll-up Door Certified & Approved According to ATEX – DYNACO S-535

High Speed Roll-up Door Certified & Approved According to ATEX – DYNACO S-545
High Speed Roll-up Door Certified & Approved According to ATEX – DYNACO S-545
Dynaco S-545 high speed roll-up ATEX doors are suitable for use in outdoor hazardous area applications in Zone 2 (Gas) and Zone 22 (Dust) potentially explosive atmospheres – the high performance doors are approved and certified according to the ATEX Directive by the Apragaz notified body.
All metal parts of the Dynaco S-545 hazardous area doors are made from corrosion resistant stainless steel whilst the non-metallic parts are composed of antistatic or electrical conductive materials – the construction of the doors ensures they avoid the build up of static electricity that could led to a spark in flammable gas/dust environments, collectively referred to as hazardous area zones, according to the level of explosion risk defined by the ATEX Directive.
💡 STOP & CHECK – Are you compliant? Is your current high speed door an accident waiting to happen? There are many high speed doors installed which have been accepted as compliant because they have an ATEX certified motor. This does not even begin to mitigate the spark potential from such a piece of equipment. If you are concerned, please do not hesitate to contact our team for advice.
Tutorial | Specifying Compliant ATEX Doors for Hazardous Areas & Explosive Atmospheres
Ask us to calculate your temperature losses and confirm the expected annual energy savings by installing high speed doors.
Explosive Atmospheres & Hazardous Area Locations & Workspaces
As well as being certified according to ATEX Directive for Zone 2 & Zone 22 hazardous area locations the Dynaco S-545 range of doors are also wind resistant up to wind load class 4 according to European standards. Efficient operating speed and superior sealing properties enable this ATEX door to improve traffic flows, provide employee comfort and save money on energy costs.
Dynaco S-545 doors are fully self-reinserting and therefore will automatically reinsert itself if the the curtain is accidentally hit.
Apragaz are an official inspection authority for equipment used in potentially explosive atmospheres.
Their unique design provides virtually perfect sealing, making the doors airtight and protecting your environment against drafts, humidity and dirt.
The curtain automatically reinserts itself when dis-lodged. No repair costs, no production downtime.
💡 Handling Drums In Hazardous Areas? ➡
Technical Specification
Zone 22 is defined as a “hazardous atmosphere formed by a dust cloud that is not likely to occur in normal operation and if so, only for a short period of time. Accumulations and layers of combustible dusts are present.” As part of explosion protection measures for, it is critical that prevention and mitigation against risk form the basis of a safe working environment. Preventing an explosive dust cloud from occurring is the primary method but this cannot always be achieved. The next step is to remove ignition sources such as electrical and non-electrical devices, hot surfaces and electrostatic discharges. Further mitigation measures may include partial inerting, isolating (making sections), venting and good housekeeping. Equipment used within such areas should be certified in line with the ATEX directive.
Potentially explosive atmospheres in the food industry include flour mills and the logistics and storage warehouses for custard powder, instant coffee, sugar, dried milk, potato powder and soup powder – including Zones 1 (21) and Zones 2 (22) we can assist with the upgrade of traditional fluorescent to modern technology brilliant white-light LED hazardous area lighting systems.
The indicated class for wind resistance applies for maximum dimensions.
* For doors up to W 4.000mm x H 5.500mm: Class 4
** Valid for a door of 3500 x 3500mm
II 3 G/D
Ex h IIC T6 EPL Gb
Ex h IIIC 85°C EPL Db
Ex db mc ia e IIC T4 EPL Gc
Ex tb mc tD IIIB 135°C EPL Dc
CE 0029 APRAGAZ 16ATEX 0150X/1
T ambient -10°C to 45°C
All indicated dimensions are net: the space necessary for mounting and maintenance has to be provided. Reduced dimensions: upon request.
The Dynaco range of High Speed Roll-up Doors include options for interior and exterior applications for use in explosive gas and dust atmospheres. An overview and certification details can be found below. Refer to individual door product pages for full specification details.
EMBED FLIPBOOK
| Category | ATEX Doors |
|---|
| Edge detection via intrinsic safety barrier | Standard earthing kit | ATEX motor, gearbox and encoder |
| Complete structure in stainless steel | All synthetic parts in antistatic material | Side reinforcement |
| Max. Dimensions | W 5.500 mm x H 5.500 mm |
| Opening speed Closing speed | Maximum 1 m/s 1 m/s |
| Structure | Stainless steel: 80 x 40 x 3 mm. |
| Drum | Stainless steel – Ø 102 x 1.2 mm. |
| Side guides | Reinforced antistatic polyethylene (PEUHMW1000 carbon black) on springs. Lower 300mm of side guides reinforced. |
| Motor | 4 poles, without brake. Ex d Power 1,5 kW – IP rating: IP 66 |
| Control box | DYNALOGIC 2 (600x600x210mm) provided with: circuit breaker, general divider, adjustable timer, push button for opening and reset, emergency stop and Ex i switching amplifier. IP rating: IP 65. Frequency inverter. Always to be installed outside the danger zone. Optional: DYNALOGIC 5 (500x500x250mm). |
| Standard detectors | Ex ia infrared barrier: 300 mm from the floor. Bottom edge detection via intrinsic safety barrier |
| Power supply Frequency | Single phase 230V – 16 A Frequency: 50-60 Hz |
| Available colours comparable with: | Black RAL9005 (Actual colour may deviate. Colour sample available upon request) |
| Reference | Standard | Test acc. | Results |
| Water permeability | EN 12425 | EN 12489 | Class 3 |
| Wind load | EN 12424 | EN 12444 | Class 4* |
| Wind permeability | EN 12426 | EN 12427 | Class 1** |
| Safe openings | EN 12453 | EN 12445 | Pass |
| Mechanical resistance | EN 12604 | EN 12605 | Pass |
| Unintended movements | EN 12604 | EN 12605 | Pass |
| Thermal transmittance | EN 12428 | EN 12428 | 6,02 W/m²K |
| Performance (cycles) | EN 12604 | EN 12605 | NPD |
| ZONE 1 & 21 ATEX DOOR – ALL WEATHER | ZONE 1 & 21 ATEX DOOR – POWER | ZONE 1 & 21 ATEX DOOR – COMPACT |
| S-559 is suitable for use in Zone 1 and Zone 21 explosive atmospheres and is specifically designed for outdoor use. The ATEX door is wind resistant up to wind load class 5. | S-549 is suitable for use in Zone 1 & Zone 21 explosive atmospheres. The ATEX door is designed for outdoor use and is wind resistant up to wind load class 4. | S-539 is suitable for use in Zone 1 & Zone 21 explosive atmospheres and is specifically designed for hazardous area indoor applications. |
| Ex II 2 G/D Ex h T4 135°C Ex db ia e IIC T4 EPL Gb Ex tb ia IIIB 135°C EPL Db | Ex II 2 G/D Ex h T4 135°C Ex db ia e IIC T4 EPL Gb Ex tb ia IIIB 135°C EPL Db CE 0029 APRAGAZ 17 ATEX 0157 X | Ex II 2 G/D Ex h T4 135°C Ex db ia e IIC T4 EPL Gb Ex tb ia IIIB 135°C EPL Db CE 0029 APRAGAZ 17 ATEX 0157 X |
| ZONE 2 & 22 ATEX DOOR – ALL WEATHER | ZONE 2 & 22 – ATEX DOOR – POWER | ZONE 2 & 22 – ATEX DOOR – COMPACT |
| S-555 is suitable for use in Zone 2 & 22 explosive atmospheres and is specifically designed for outdoor use. The ATEX door is wind resistant up to wind load class 5. EX II 3 G/D Ex h IIC T6 EPL Gb Ex h IIIC 85°C EPL Db Ex db mc ia e IIC T4 EPL Gc Ex tb mc tD IIIB 135°C EPL Dc CE 0029 APRAGAZ 16ATEX 0150X/1 | S-545 is suitable for use in Zone 2 & 22 explosive atmospheres. The ATEX door is designed for outdoor use and is wind resistant up to wind load class 4. EX II 3 G/D Ex h IIC T6 EPL Gb Ex h IIIC 85°C EPL Db Ex db mc ia e IIC T4 EPL Gc Ex tb mc tD IIIB 135°C EPL Dc CE 0029 APRAGAZ 16ATEX 0150X/1 | S-535 is suitable for Zone 2 & Zone 22 explosive atmospheres and is specifically designed for hazardous area indoor applications. EX II 3 G/D Ex h IIC T6 EPL Gb Ex h IIIC 85°C EPL Db Ex db mc ia e IIC T4 EPL Gc Ex tb mc tD IIIB 135°C EPL Dc CE 0029 APRAGAZ 16ATEX 0150X/1 |
Tell us your quantity and requirements — we reply within one business day.
ATEX Doors | Dynaco S-559 Zone 1 & 21 High Speed Door – All WeatherHigh Speed Roll-up Door Certified & Approved According to ATEX – DYNACO S-535
ATEX DoorsHigh Speed Roll-up Door Certified & Approved According to ATEX – DYNACO S-555
ATEX DoorsCompact High Speed Roll-up Door Certified & Approved According to ATEX – DYNACO S-539
Share your specifications and quantities. Our team will review your request and come back with sourcing options and a quotation.