ATEX High Bay Lights | Zone 1 LED Hazardous Area LightingATEX High Bay Lights | Zone 21 High Power Bay Light Hazardous Area 20,000 Lumens
Raytec HPBY20K | High Bay Lights Zone 21 20,000 Lumens
Product category

ATEX High Bay Lights | Zone 1 LED Hazardous Area LightingRaytec HPBY20K | High Bay Lights Zone 21 20,000 Lumens
ATEX High Bay Lights | Zone 1 LED Hazardous Area LightingRaytec HPBY15K | High Bay Lights Zone 21 15,000 Lumens
ATEX High Bay Lights | Zone 1 LED Hazardous Area LightingRaytec HPBY10K | High Bay Lights Zone 21 10,000 Lumens
ATEX High Bay Lights | Zone 1 LED Hazardous Area LightingRaytec HPBY15K | High Bay Lights Zone 1 & Zone 21 15,000 Lumens
ATEX High Bay Lights | Zone 1 LED Hazardous Area LightingRaytec HPBY10K | High Bay Lights Zone 1 & Zone 21 10,000 Lumens
ATEX High Bay Lights | Zone 1 LED Hazardous Area LightingRaytec HPBY25K | High Bay Lights Zone 21 25,000 Lumens
ATEX High Bay Lights | Zone 1 LED Hazardous Area LightingRaytec HPBY20K | High Bay Lights Zone 1 & Zone 21 20,000 Lumens
ATEX High Bay Lights | Zone 1 LED Hazardous Area LightingRaytec HPBY25K | High Bay Lights Zone 1 & Zone 21 25,000 Lumens
Send us the specification — we source beyond the catalogue.
Send Your RequirementZone 1 high bays (category 2G) are certified for areas where an explosive gas atmosphere is likely during normal operation – for example above filling lines, inside solvent recovery buildings, paint mixing rooms, refinery process buildings and offshore modules. Versions marked 2D are also suitable for Zone 21 dust areas such as flour, sugar and grain handling.
To be safe where gas is present during operation, Zone 1 high bays use flameproof (Ex d) or combined Ex de construction for the LED and driver compartments, with heavy cast aluminium bodies and toughened glass. That makes them heavier than Zone 2 fittings, so check the ceiling structure and use the supplied safety wire.
| Check | Why it matters |
|---|---|
| Gas group (IIB or IIC) | IIC is required for hydrogen and acetylene areas |
| Temperature class (T4, T5, T6) | Must stay below the ignition temperature of the gas or dust |
| Dust marking (Ex tb, IIIC) | Needed for Zone 21 combustible dust |
| Lumen output and optic | Sets the number of fittings and light uniformity |
| Weight and mounting | Heavier housings need suitable steelwork |
For lower-risk areas, compare our Zone 2 high bays.
Request a quote with your zone, gas group, quantities and delivery country – we reply with prices, certificates and lead times.
Yes. Equipment certified for Zone 1 (category 2G) can always be installed in Zone 2.
They normally use flameproof Ex d or Ex de construction, which needs thick cast housings and toughened glass to contain any internal ignition.
Versions marked Ex tb IIIC (category 2D) are certified for Zone 21 and Zone 22 combustible dust areas. Check the marking of each model.
Share your specifications and quantities. Our team will review your request and come back with sourcing options and a quotation.