Hazardous Area & Process Heating For Zone 1 & Zone 2 LocationsDrum Heater Lid – Isopad FIDR-LID
Thermocoax Isopad FIDR-LID is an insulated lid for use with the FIDR range of ATEX drum heater enclosures.

Thermocoax Isopad FIGB-SR gas bottle heaters are a heavy duty heated enclosure designed specifically to solve the issues associated with gas usage in cold climates such as gas separation, gas liquefaction and…
Thermocoax Isopad FIGB-SR gas bottle heaters are a heavy duty heated enclosure designed specifically to solve the issues associated with gas usage in cold climates such as gas separation, gas liquefaction and reduced capacity.
The FIGB-SR gas bottle heater is constructed from heavy gauge sheet steel with a double skin construction housing the electric heating elements which cover the entire inner surface ensuring the gas bottle is heated consistently. These heating elements are insulated to prevent heat loss through the outer wall and the inner walls are also painted with a thermally conductive paint to give maximum heat transfer. The clam shell design and castors allow the gas bottle heaters to be wheeled up to and closed around the gas bottle, eliminated overhead lifting.
Thermocoax Isopad FIGB-SR gas bottle heaters are ATEX and IECEx approved for use within Zone 1 and Zone 2 hazardous area applications and are equipped with a self-regulating heating system as standard.
FIGB-SR gas bottle heaters are available for 10, 20, 40, 50 and 79 litre gas cylinder sizes with a 277V power supply.
| Category | ATEX Electric & Process Heaters |
|---|
| Area Classification | Hazardous Area |
| Hazardous Area Zone | Gas – Zone 1 & 2 Dust – Zone 21 & 22 |
| Temperature Class | T2, T4, T6 |
| Ingress Protection | IP6X (IP65) |
| Electrical Protection Class | Class I |
| Ambient Temperature Range | -40ºC to +50ºC |
| Approvals | System Approval by Baseefa |
| Number of Certificate | Baseefa08ATEX0280X / IECEx BAS 08.0088X |
| Marking | Ex II GD Ex de IIC T2 … T6 Ex tD A21 IP6X T240ºC … T80ºC |
| Norms | EN, IEC Standard |
| Height | 750, 1130, 1350, 1400mm |
| Inner Diameter | 150, 214, 239, 328mm |
| Outer Diameter | 250, 314, 339, 428mm |
| Heater Type | Self Regulating Heating Cable |
| Carrier | Sheet Metal Steel |
| Material of Thermal Insulation | Glass Fibre |
| Thickness | 40mm |
| Outer Protection | Sheet Metal Steel |
| Paint | Matt Black Heat Resistant & Structured Blue Paint |
| Fixation & Closure Type | Quick-Snap Fastener |
| Junction Box (Type) | STAHL Series 8118 |
| Ingress Protection | IP66 |
| Maximum Ambient Temperature | -50ºC to +55ºC |
| Maximum Connecting Cross Section | 4mm² |
| Terminals | 8 |
| Glands | 4 x M25 |
| Housing Material | Polyester Glass Fibre Reinforced |
| Connection Lead Length | 2m |
| Lead Cross Section | 4mm² |
| Maximum Operating Temperature | 180ºC |
| Connection Lead Insulation Material | Silicone |
| Thermostat (Type) | RAYSTAT-EX-02 |
| Sensor Type | Capillary Type |
| Controller Range | -4ºC to +163ºC |
| Ingress Protection | IP65 |
| Maximum Ambient Temperature | -40ºC to +60ºC |
| Housing Material | Aluminium |
| Frequency | 50-60Hz |
| Maximum Operating Voltage | 277 Vac (~1ph) |
| Maximum Operating Temperature | 65ºC to 120ºC (depends on heating cable type and temperature class) |
| Options | Design with other housing materials (e.g stainless steel) Alternative junction box type JBU-100-L-E with signal lamp for operating status (ON/OFF) |
| For Standard Sizes (Ltr) | Height (mm) | Inner Diameter (mm) | Outer Diamter (mm) | Nominal Power (W) | Nominal Voltage (VAC) | Weight (kg) |
| 10 | 750 | 150 | 250 | 630 | 230 | 14 |
| 10 | 750 | 150 | 250 | 640 | 230 | 14 |
| 10 | 750 | 150 | 250 | 290 | 230 | 14 |
| 20 | 750 | 214 | 314 | 820 | 230 | 18 |
| 20 | 750 | 214 | 314 | 830 | 230 | 18 |
| 20 | 750 | 214 | 314 | 380 | 230 | 18 |
| 40 | 1400 | 214 | 314 | 1550 | 230 | 30 |
| 40 | 1400 | 214 | 314 | 1570 | 230 | 30 |
| 40 | 1400 | 214 | 314 | 710 | 230 | 30 |
| 50 | 1350 | 239 | 339 | 1490 | 230 | 32 |
| 50 | 1350 | 239 | 339 | 1510 | 230 | 32 |
| 50 | 1350 | 239 | 339 | 680 | 230 | 32 |
| 79 | 1130 | 328 | 428 | 1510 | 230 | 37 |
| 79 | 1130 | 328 | 428 | 1540 | 230 | 37 |
| 79 | 1130 | 328 | 428 | 700 | 230 | 37 |
Tell us your quantity and requirements — we reply within one business day.
Hazardous Area & Process Heating For Zone 1 & Zone 2 LocationsThermocoax Isopad FIDR-LID is an insulated lid for use with the FIDR range of ATEX drum heater enclosures.
Hazardous Area & Process Heating For Zone 1 & Zone 2 LocationsThermocoax Isopad FIBDR-SRQ ATEX base drum heaters are designed to provide medium flow and process temperature to 200 litre steel drums in Zone 1 and Zone 2 hazardous areas.
Hazardous Area & Process Heating For Zone 1 & Zone 2 LocationsThermocoax Isopad FIBDR-SRB ATEX base drum heaters are designed to provide medium flow and process temperature to 200 litre steel drums in Zone 1 and Zone 2 hazardous areas.
Share your specifications and quantities. Our team will review your request and come back with sourcing options and a quotation.