Marine CablesM2XH (NOFI) Marine Cable
Used as fixed installation cables in various electromechanical and electronic equipments of marine vehicles, in most areas & on open deck in ships.

Used as signal and communication cables in radio, radar and information systems of marine vehicles. It’s twisted pairs enables proper transmission of high frequency signals, while it’s overall screen minimizes…
Used as signal and communication cables in radio, radar and information systems of marine vehicles. It’s twisted pairs enables proper transmission of high frequency signals, while it’s overall screen minimizes environmental electromagnetic interference.
| Conductor | Electrolytic annealed, class 5 stranded plain copper wires ( tinned conductor on request) |
|---|---|
| Conductor | EN 50525-2-21, DIN VDE 0282-4, BS 6500 BS 7919, IEC 60245-4 |
| Insulation | EI4 Type rubber (EPR) compound |
| Outer sheath | EM2 Type elastomer compound |
| Working temperature in mobile use | -25ºC / +60ºC |
| Separator | A suitable tape may be applied over the conductor |
| Core identification | Acc. to HD 308 |
| Inner sheath | EM2 or EM3 type elastomer compound (if outer sheath thickness is greater than 2.4 mm) |
| Color | Black (other colors on request) |
| General requirements | EN 50525-1, HD 22.1, DN VDE 0282-1, IEC 60245-1 |
| Guide to use | HD 516, DIN VDE 0298-300 |
| Electrical tests | EN 50395, IEC 60245-2 |
| Non – electrical tests | EN 50396, IEC 60245-2 |
| Conductor resistance | EN / IEC 60228, HD 383, DIN VDE 0295, BS 6360 |
| In fixed use | -35ºC / +85ºC |
| Conductor short – circuit temp. | Max. 200ºC |
| Temp. on cable surface | Max. +50ºC |
| Min. installation temp. | -25ºC |
| Min. bending radius | HD 516 Table 6.C |
| Max. tensile load | 15 N / mm2 |
| Current carrying capacities | HD 516 Table 7.C VDE 0298-4 |
| Flame retardant | EMEC 60332-1-2, DIN VDE 0482-332-1-2 |
| Oil resistant | HD/EMEC 60811-2-1, DIN VDE 0473-811-2-1 |
| UV and sunlight resistance | EN 50289-4-17 A&B, ISO 4892-2&3 |
| Cross Section (mm²) | Overall Diameter (mm) | Approximate Weight (kg / km) | Min. Bending Radius Fixed Installed (mm) | Max Resistance of Conductors at 20°C (ohm / km) | Current Carrying Capacity at 45°C (A) |
|---|---|---|---|---|---|
| 1×1,5 | 6 | 52 | 24 | 13.3 | 19 |
| 1×2,5 | 6.4 | 65 | 25 | 7.98 | 26 |
| 1×10 | 10.2 | 185 | 41 | 1.91 | 60 |
| 1×16 | 11 | 245 | 44 | 1.21 | 79 |
| 1×25 | 13.8 | 375 | 56 | 0.78 | 104 |
| 1×35 | 15.3 | 490 | 62 | 0.554 | 129 |
| 1×50 | 17.8 | 678 | 72 | 0.386 | 162 |
| 1×70 | 19.4 | 890 | 78 | 0.272 | 202 |
| 1×95 | 22.1 | 1152 | 89 | 0.206 | 240 |
| 1×120 | 24.4 | 1450 | 98 | 0.161 | 280 |
| 1×150 | 26.6 | 1750 | 107 | 0.129 | 321 |
| 1×185 | 29.7 | 2165 | 119 | 0.106 | 363 |
| 1×240 | 32.6 | 2740 | 131 | 0.0801 | 433 |
| 1×300 | 35.6 | 3356 | 143 | 0.0641 | 497 |
| 2×1 | 8.4 | 98 | 34 | 19.5 | 16 |
| 2×1,5 | 9.3 | 122 | 38 | 13.3 | 19 |
| 2×2,5 | 10.6 | 165 | 43 | 7.98 | 26 |
| 2×4 | 12.2 | 230 | 49 | 4.95 | 43 |
| 2×6 | 13.6 | 300 | 55 | 3.3 | 60 |
| 2×10 | 19.2 | 572 | 77 | 1.91 | 79 |
| 2×16 | 21 | 740 | 84 | 1.21 | 104 |
| 2×25 | 26.7 | 1160 | 107 | 0.78 | 129 |
| 2×35 | 29.4 | 1465 | 118 | 0.554 | 162 |
| 2×50 | 34.4 | 2030 | 138 | 0.386 | 202 |
| 2×70 | 38.3 | 2645 | 154 | 0.272 | 240 |
| 2×95 | 43.7 | 3435 | 175 | 0.206 | 280 |
| 2×120 | 49.5 | 4430 | 198 | 0.161 | 321 |
| 2×150 | 52.3 | 5110 | 210 | 0.129 | 363 |
| 3×1 | 9.1 | 118 | 37 | 19.5 | 13 |
| 3×1,5 | 9.9 | 145 | 40 | 13.3 | 16 |
| 3×2,5 | 11.4 | 205 | 46 | 7.98 | 21 |
| 3×4 | 13.1 | 280 | 53 | 4.95 | 29 |
| 3×6 | 14.6 | 370 | 59 | 3.3 | 36 |
| 3×10 | 20.6 | 705 | 83 | 1.91 | 51 |
| 3×16 | 22.5 | 920 | 90 | 1.21 | 67 |
| 3×25 | 28.6 | 1435 | 115 | 0.78 | 109 |
| 3×35 | 31.7 | 1845 | 127 | 0.554 | 135 |
| 3×50 | 37 | 2550 | 148 | 0.386 | 169 |
| 3×70 | 40.9 | 3330 | 164 | 0.272 | 211 |
| 3×95 | 46.9 | 4350 | 188 | 0.206 | 250 |
| 3×120 | 51.6 | 5410 | 207 | 0.161 | 292 |
| 3×150 | 56.2 | 6515 | 225 | 0.129 | 335 |
| 3×185 | 62.3 | 8050 | 250 | 0.106 | 378 |
| 3×240 | 69.5 | 10270 | 278 | 0.0801 | 447 |
| 4×1 | 10.1 | 150 | 41 | 19.5 | 13 |
| 4×1,5 | 11 | 180 | 44 | 13.3 | 16 |
| 4×2,5 | 12.6 | 252 | 51 | 7.98 | 21 |
| 4×4 | 14.5 | 355 | 58 | 4.95 | 30 |
| 4×6 | 16.3 | 470 | 66 | 3.3 | 37 |
| 4×10 | 22.6 | 870 | 91 | 1.91 | 52 |
| 4×16 | 24.7 | 1150 | 99 | 1.21 | 69 |
| 4×25 | 31.8 | 1815 | 127 | 0.78 | 92 |
| 4×35 | 35.2 | 2335 | 141 | 0.554 | 114 |
| 4×50 | 41.1 | 3235 | 165 | 0.386 | 143 |
| 4×70 | 45 | 4225 | 180 | 0.272 | 178 |
| 4×95 | 52 | 5560 | 208 | 0.206 | 210 |
| 4×120 | 56.8 | 6870 | 228 | 0.161 | 246 |
| 4×150 | 62.2 | 8320 | 249 | 0.129 | 282 |
| 4×185 | 69.7 | 10340 | 279 | 0.106 | 319 |
| 4×240 | 77.6 | 13180 | 311 | 0.0801 | 377 |
| 5×1 | 11.1 | 175 | 45 | 19.5 | 10 |
| 5×1,5 | 12.1 | 214 | 49 | 13.3 | 16 |
| 5×2,5 | 13.8 | 300 | 56 | 7.98 | 23 |
| 5×4 | 16.1 | 428 | 65 | 4.95 | 30 |
| 5×6 | 18.1 | 570 | 73 | 3.3 | 38 |
| 5×10 | 24.9 | 1065 | 100 | 1.91 | 54 |
| 5×16 | 27.4 | 1420 | 110 | 1.21 | 71 |
| 5×25 | 35.4 | 2250 | 142 | 0.78 | 94 |
| 5×35 | 38.9 | 2875 | 156 | 0.554 | 89 |
| 5×50 | 45.8 | 4025 | 185 | 0.386 | 114 |
| 5×70 | 50.2 | 5270 | 201 | 0.272 | 140 |
| 7×1,5 | 15.4 | 350 | 62 | 13.3 | 16 |
| 7×2,5 | 17.5 | 480 | 70 | 7.98 | 23 |
| 10×1,5 | 18.3 | 455 | 74 | 13.3 | 16 |
| 12×1,5 | 18.7 | 502 | 75 | 13.3 | 16 |
| 14×1,5 | 19.9 | 575 | 58 | 13.3 | 16 |
| 19×1,5 | 23.2 | 782 | 93 | 13.3 | 16 |
| 24×1,5 | 25.7 | 922 | 103 | 13.3 | 16 |
Tell us your quantity and requirements — we reply within one business day.
Marine CablesUsed as fixed installation cables in various electromechanical and electronic equipments of marine vehicles, in most areas & on open deck in ships.
Marine CablesUsed as fixed installation cables in various electromechanical and electronic equipments of marine vehicles. Due to its’ overall screen, environmental electromagnetic interference is minimized.
Marine CablesUsed as fixed installation cables in various electromechanical and electronic equipments of marine vehicles.
Share your specifications and quantities. Our team will review your request and come back with sourcing options and a quotation.