Marine CablesM2XH (NOFI) Marine Cable
Used as fixed installation cables in various electromechanical and electronic equipments of marine vehicles, in most areas & on open deck in ships.

Used on marine vehicles as fixed installation cables of various electromechanical and electronic equipments, where sustainable connection during fire is required.
Used on marine vehicles as fixed installation cables of various electromechanical and electronic equipments, where sustainable connection during fire is required.
* Minimum recommended installation temperature -15°C
For core identification, diameter tolerances and current ratings etc. see technical information section
| Conductor | Electrolytic, stranded, annealed sector shaped copper wire to IEC 60228 Class 5 SM (Tinned on request) |
|---|---|
| Insulation | Cross linked polyethylene compound (XLPE) |
| Outer sheath | Halogen-free, flame retardant and fire resistant, UV resistant, thermoplastic polyolefin based compound (SHF1) |
| Fire barrier | Mica tape |
| Inner covering | Separating foil |
| Screen | Electrolytic copper braided screen (min 90% coverage) (Tinned copper wire braid on request) |
| Color | Orange or Green or Black |
| Nominal Cross-Section (mm²) | Cable Outer Diameter (mm) | Approximate Cable Weight (kg/km) | Minimum bending radius (fixed) (mm) | Maximum Conductive Resistance at 20°C (ohms/km) | Current carrying capacity at 45°C (A) |
|---|---|---|---|---|---|
| 3×35 | 23.6 | 1310 | 142 | 0.554 | 107 |
| 3×50 | 28 | 1800 | 168 | 0.386 | 137 |
| 3×120 | 40.2 | 4035 | 242 | 161 | 233 |
| 3×150 | 44.1 | 4870 | 265 | 0.129 | 268 |
| 3×185 | 49 | 6000 | 294 | 0.106 | 303 |
| 3×240 | 54.4 | 7640 | 327 | 0.0801 | 356 |
| 4×35 | 27.6 | 1720 | 166 | 0.554 | 107 |
| 4×50 | 31.3 | 2330 | 188 | 0.386 | 137 |
| 4×70 | 36.7 | 3250 | 221 | 0.272 | 168 |
| 4×95 | 40 | 4140 | 240 | 0.206 | 201 |
| 4×120 | 45.3 | 5250 | 272 | 0.161 | 233 |
| 4×150 | 48.4 | 6310 | 291 | 0.129 | 268 |
| 4×185 | 53.8 | 7780 | 323 | 0.106 | 303 |
| 4×240 | 59.3 | 9920 | 356 | 0.0801 | 356 |
| Cross section (mm2) | Overall diameter (mm) | Approximate weight (kg / km) | Min. bending radius, fixed (mm) | Max. conductor resistance at 20 °C (ohm / km) | Current-carrying capacity at 45 °C (A) |
|---|---|---|---|---|---|
| 3×35 | 23.6 | 1310 | 142 | 0.554 | 107 |
| 3×50 | 28 | 1800 | 168 | 0.386 | 137 |
| 3×120 | 40.2 | 4035 | 242 | 161 | 233 |
| 3×150 | 44.1 | 4870 | 265 | 0.129 | 268 |
| 3×185 | 49 | 6000 | 294 | 0.106 | 303 |
| 3×240 | 54.4 | 7640 | 327 | 0.0801 | 356 |
| 4×35 | 27.6 | 1720 | 166 | 0.554 | 107 |
| 4×50 | 31.3 | 2330 | 188 | 0.386 | 137 |
| 4×70 | 36.7 | 3250 | 221 | 0.272 | 168 |
| 4×95 | 40 | 4140 | 240 | 0.206 | 201 |
| 4×120 | 45.3 | 5250 | 272 | 0.161 | 233 |
| 4×150 | 48.4 | 6310 | 291 | 0.129 | 268 |
| 4×185 | 53.8 | 7780 | 323 | 0.106 | 303 |
| 4×240 | 59.3 | 9920 | 356 | 0.0801 | 356 |
Tell us your quantity and requirements — we reply within one business day.
Marine CablesUsed as fixed installation cables in various electromechanical and electronic equipments of marine vehicles, in most areas & on open deck in ships.
Marine CablesUsed as fixed installation cables in various electromechanical and electronic equipments of marine vehicles. Due to its’ overall screen, environmental electromagnetic interference is minimized.
Marine CablesUsed as fixed installation cables in various electromechanical and electronic equipments of marine vehicles.
Share your specifications and quantities. Our team will review your request and come back with sourcing options and a quotation.