Marine CablesM2XH (NOFI) Marine Cable
Used as fixed installation cables in various electromechanical and electronic equipments of marine vehicles, in most areas & on open deck in ships.

Used on marine vehicles as fixed installation cables of various electromechanical and electronic equipments, where sustainable connection during fire is required.
Used on marine vehicles as fixed installation cables of various electromechanical and electronic equipments, where sustainable connection during fire is required.
*Minimum recommended installation temperature -15°C
For core identification, diameter tolerances and current ratings etc. see technical information section
| Rated voltage | 0,6 / 1 kV |
|---|---|
| Conductor | Electrolytic, stranded, annealed copper wire IEC 60228 Class 5 (Class 2 and / or tinned on request) |
| Insulation | Cross linked polyethylene compound (XLPE) |
| Outer sheath | Halogen-free, flame retardant, UV resistant, thermoplastic polyolefin based compound (SHF 1) |
| Working temperature | -40°C / + 90°C |
| Fire barrier | Mica tape |
| Inner covering | Halogen-free compound |
| Color | Orange or Green |
| FI | With extruded bedding compound |
| Construction | IEC 60092 / 353 |
| Tests and material | IEC 60092 / 350-360 |
| Flame retardant | IEC 60332 / 1-2, IEC 60332 / 3-22 Cat A |
| Fire resistant | IEC 60331 / 21, IEC 60331 / 1-2 |
| Halogen content | IEC 60754 / 1-2 |
| Smoke emission | IEC 61034 / 1-2 (DIN EN 50268 / 1-2) |
| Ozon resistance | IEC 60811 / 403 |
| Min. bending radius (fixed) | For cables D ≤ 25 mm 4xD, For cables D > 25 mm 6xD |
| Test voltage | 3,5 kV |
| UV and sunlight resistance | EN 50289-4-17 A&B, ISO 4892-2&3 |
| MGM 110 DOUBLE LA VER ARMOURED SIGNAL CABLE | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Cross section | 2×1,5 | 4×1,5 | 7×1,5 | 10×1,5 | 12×1,5 | 14×1,5 | 19×1,5 | 37×1,5 | 61×1,5 | 91×1,5 | |||
| Conductors | |||||||||||||
| Conductor diameter | Nam. mm | 1.50 | |||||||||||
| lnsu/ation thickness | mm | 0.5 | |||||||||||
| Core diameter | mm | 2,36 (min) – 2,64 (max) | |||||||||||
| Cable details | |||||||||||||
| Radia/ thickness of inner sheath | mm | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.2 | 1.2 | 1.4 | ||
| Size of armour | mm | 1/0,9 | 1/0,9 | 1/0,9 | 1/1,25 | 1/1,25 | 1/1,25 | 1/1,25 | 1/1,6 | 1/1,6 | 1/2,0 | ||
| Radial thickness of outer sheath | mm | 1.5 | 1.6 | 1.6 | 1.7 | 1.7 | 1.7 | 1.8 | 1.9 | 2.1 | 2.3 | ||
| Min. overa/1 diameter | mm | 15.9 | 17.0 | 17.5 | 22.8 | 23.2 | 23.8 | 25.3 | 32.5 | 37.7 | 45.1 | ||
| Max. overa/1 diameter | mm | 17.3 | 18.6 | 19.1 | 24.4 | 24.8 | 25.8 | 27.3 | 34.9 | 40.1 | 47.9 | ||
| Min. bending radius | mm | 156 | 168 | 172 | 220 | 224 | 233 | 246 | 315 | 361 | 432 | ||
| Appx. cab/e weight | kg/km | 570 | 680 | 820 | 1,280 | 1,350 | 1,450 | 1,650 | 2,850 | 3,000 | 5,600 | ||
| Copper weight | kg/km | 30 | 60 | 105 | 150 | 180 | 210 | 280 | 540 | 880 | 1,315 | ||
| MGM 110 DOUBLE LA VER ARMOURED TELEPHONE CABLE | |||||||||||||
| Cross section | 1x2x1,5 | 2x2x1,5 | 4x2x1,5 | 7x2x1,5 | 10x2x1,5 | 12x2x1,5 | 19x2x1,5 | 27x2x1,5 | 30x2x1,5 | 37x2x1,5 | 48x2x1,5 | 61x2x1,5 | |
| Conductors | |||||||||||||
| Number and cross section | mm2 | 1x2x1,5 | 2x2x1,5 | 4x2x1,5 | 7x2x1,5 | 10x2x1,5 | 12x2x1,5 | 19x2x1,5 | 27x2x1,5 | 30x2x1,5 | 37x2x1,5 | 48x2x1,5 | 61x2x1,5 |
| Stranding | mm | 7/0,5 | |||||||||||
| Conductor diameter | Nam. mm | 1.50 | |||||||||||
| lnsu/ation thickness | mm | 0.5 | |||||||||||
| Core diameter | mm | 2,36 (min) – 2,64 (max) | |||||||||||
| Cable details | |||||||||||||
| Radia/ thickness of inner sheath | mm | 1.0 | 1.0 | 1.0 | 1.0 | 1.2 | 1.2 | 1.2 | 1.4 | 1.4 | 1.4 | 1.4 | 1.6 |
| Size of armour | mm | 1/0,9 | 1/0,9 | 1/1,25 | 1/1,25 | 1/1,6 | 1/1,6 | 1/1,6 | 1/2,0 | 1/2,0 | 1/2,0 | 1/2,0 | 1/2,5 |
| Radial thickness of outer sheath | mm | 1.4 | 1.5 | 1.6 | 1.7 | 1.9 | 1.9 | 2.0 | 2.2 | 2.2 | 2.3 | 2.4 | 2.6 |
| Min. overa/1 diameter | mm | 15.9 | 17.0 | 22.7 | 25.3 | 32.0 | 32.4 | 36.2 | 43.6 | 44.7 | 47.3 | 52.5 | 58.8 |
| Max. overa/1 diameter | mm | 17.3 | 18.6 | 24.4 | 27.3 | 34.0 | 34.8 | 38.6 | 46.2 | 47.3 | 50.1 | 55.3 | 62.0 |
| Min. bending radius | mm | 156 | 168 | 220 | 246 | 306 | 314 | 348 | 416 | 426 | 451 | 498 | 558 |
| Appx. cab/e weight | kg/km | 570 | 680 | 1,250 | 1,580 | 2,350 | 2,550 | 3,280 | 4,680 | 4,950 | 5,620 | 6,590 | 8,800 |
| Copper weight | kg/km | 30 | 60 | 120 | 210 | 290 | 350 | 550 | 780 | 870 | 1,070 | 1,390 | 1,760 |
Tell us your quantity and requirements — we reply within one business day.
Marine CablesUsed as fixed installation cables in various electromechanical and electronic equipments of marine vehicles, in most areas & on open deck in ships.
Marine CablesUsed as fixed installation cables in various electromechanical and electronic equipments of marine vehicles. Due to its’ overall screen, environmental electromagnetic interference is minimized.
Marine CablesUsed as fixed installation cables in various electromechanical and electronic equipments of marine vehicles.
Share your specifications and quantities. Our team will review your request and come back with sourcing options and a quotation.