Type P Power Cable Single Conductor 2kV Armoured and Unsheathed

These cables are intended for use as power cables aboard ship and on off-shore oil rings. The cables are constructed in accordance with the recommended practice for marine cable for…

Rated voltage2 kV
ConductorSoft annealed flexible stranded tinned copper wire acc. to IEEE 1580 Table 11
InsulationCross-linked polyolefin compound, in accordance with Type P of IEEE 1580 and Type X110 of UL 1309/CSA C22.2 No.245.
SeparatorA suitable separator tape may be applied to the conductor (optional for manufacturer)
  • Quoted to your quantity
  • Documentation on request
  • International delivery

Product Overview

These cables are intended for use as power cables aboard ship and on off-shore oil rings. The cables are constructed in accordance with the recommended practice for marine cable for use on fixed or floating facilities, IEEE 1580. Excellent resistance to oil, abrasion petrochem fluids, moisture salty water and sunlight.

Technical Specifications

Rated voltage2 kV
ConductorSoft annealed flexible stranded tinned copper wire acc. to IEEE 1580 Table 11
InsulationCross-linked polyolefin compound, in accordance with Type P of IEEE 1580 and Type X110 of UL 1309/CSA C22.2 No.245.
SeparatorA suitable separator tape may be applied to the conductor (optional for manufacturer)
ArmorBasket weave bronze or tinned copper wire armour in accordance with IEEE 1580 and UL 1309/CSA C22.2 No.245
Reference standardsIEEE 1580, UL 1309, CSA C22.2 No.245, IEEE 45
Insulation materialIEEE 1580, UL 1309, CSA C22.2 No.245
Sheath materialIEEE 1580, UL 1309, CSA C22.2 No.245
Conductor materialASTM B 33
Conductor resistanceIEEE 1580 Table 11
Flame propagationIEEE 1202, IEC 60332-3
Cold bend (-40)CSA C22.2
Cold impact (-35)CSA C22.2
Temperature rating IEEE 1580100°C (Single Core 125°C)
Temperature rating UL 1309110°C (Single Core 125°C)
Test voltageIEEE 1580 Table 19
Min. bending radius6 x D
Current carrying capacityIEEE 45.8
* canCable Article Number

** Ambient air temperature at 45 °C
* This can numbers for Black outer sheath and tinned copper wire braiding

CAN*Cable TypeCross-SectionOuter Sheath DiameterApprox. Cable Weight (kg/km)Min. Bending Radius (mm)Current Carrying Capacity 100°C (**) (A)Current Carrying Capacity 110°C (**) (A)Max. Electrical Resistance at 20°C (ohm/km)
Min. (mm)Nom. (mm)Max. (mm)
6419.1SPT-2-2kV1×18 AWG7,27,99,011954161720,384
6419.4SPT-7-2kV1×12 AWG8,28,910,01616045486,292
6419.5SPT-10-2kV1×10 AWG9,09,711,02006658623,538
6419.6SPT-17-2kV1×8 AWG10,011,012,02517272772,46
6419.7SPT-26-2kV1×6 AWG11,012,013,031978961031,539
6419.8SPT-33-2kV1×5 AWG12,013,014,5402871091171,137
6419.9SPT-42-2kV1×4 AWG13,013,815,0448901281370,902
6419.10SPT-53-2kV1×3 AWG13,514,616,0520961461560,715
6419.11SPT-66-2kV1×2 AWG15,016,217,56221051691810,568
6419.12SPT-84-2kV1×1 AWG17,018,320,08181201942080,412
6419.13SPT-106-2kV1×1/0 AWG18,019,120,58991232272430,363
6419.14SPT-133-2kV1×2/0 AWG19,020,422,01.0831322622810,284
6419.15SPT-168-2kV1×3/0 AWG21,022,324,01.3431443003210,206
6419.16SPT-212-2kV1×4/0 AWG23,024,726,51.6161593513760,171
6419.17SPT-262-2kV1×262 kcmil25,026,728,51.9061714074360,148
6419.18SPT-313-2kV1×313 kcmil26,528,130,02.1541804554870,123
6419.19SPT-373-2kV1×373 kcmil28,029,732,02.4811925165530,103
6419.20SPT-444-2kV1×444 kcmil29,531,534,02.8842045886300,086
6419.21SPT-535-2kV1×535 kcmil32,534,437,03.4322226306760,072
6419.22SPT-597-2kV1×597 kcmil33,535,638,03.7522286706780,07
6419.23SPT-646-2kV1×646 kcmil35,036,839,54.0682377317830,06
6419.24SPT-777-2kV1×777 kcmil37,039,242,04.7602528228810,05
6419.25SPT-1111-2kV1×1111 kcmil45,047,450,56.7983031.0251.0980,035

Features

  • Flame retardant

Certifications / Standards

  • UL

Request Information About This Product

Tell us your quantity and requirements — we reply within one business day.

Related Products

Have a product requirement?

Share your specifications and quantities. Our team will review your request and come back with sourcing options and a quotation.